Tester Connection
|
Wiring Color
|
Terminal Description
|
Condition
|
Specified Condition
|
D33-1 (IG+) - D33-14 (GND)
|
GR - W-B
|
Power source (IG)
|
Ignition switch on (IG)
|
11 to 14 V
|
D33-2 (SOL+) - D33-14 (GND)
|
L - W-B
|
Air conditioning compressor operation signal
|
Engine idling
|
Pulse generation (see waveform 1)
|
Blower switch LO
|
Air Conditioning switch ON
|
D33-3 (PTC1) - Body ground (*1)
|
P - Body ground
|
PTC NO. 1 heater relay operation signal
|
Engine idling
|
Below 1 V → 11 to 14 V
|
Set temperature: MAX HOT
|
Engine coolant temperature: Below 65°C (149°F)
|
Ambient temperature: Below 10°C (50°F)
|
Blower switch OFF → LO
|
D33-4 (PTC3) - Body ground (*1)
|
W - Body ground
|
PTC NO. 3 heater relay operation signal
|
Engine idling
|
Below 1 V → 11 to 14 V
|
Set temperature: MAX HOT
|
Engine coolant temperature: Below 65°C (149°F)
|
Ambient temperature: Below 10°C (50°F)
|
Blower switch OFF → LO
|
D33-5 (TAM) - D33-14 (GND)
|
B - W-B
|
Ambient temperature sensor signal
|
Ignition switch on (IG)
|
1.8 to 2.2 V
|
Ambient temperature: 25°C (77°F)
|
D33-8 (LOCK) - D33-14 (GND)
|
V - W-B
|
Air compressor lock sensor signal
|
Engine idling
|
Pulse generation (see waveform 5)
|
Air Conditioning switch ON
|
Blower switch LO
|
D33-9 (PRE) - D33-13 (SG-2)
|
R - SB
|
Air conditioning pressure sensor signal
|
Refrigerant pressure: Normal
|
0.76 to 4.74 V
|
D33-9 (PRE) - D33-13 (SG-2)
|
R - SB
|
Air conditioning pressure sensor signal
|
Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2, 28 psi])
|
0.5 to 4.83 V
|
D33-9 (PRE) - D33-13 (SG-2)
|
R - SB
|
Air conditioning pressure sensor signal
|
Refrigerant pressure: Abnormal (more than 3.03 MPa [32 kgf/cm2, 455 psi])
|
4.74 V or higher
|
D33-10 (S5-3) - D33-14 (GND)
|
O - W-B
|
Power supply for pressure sensor
|
Ignition switch on (IG)
|
4.5 to 5.5 V
|
D33-11 (CANH) - D33-14 (GND)
|
LG - W-B
|
Hi-level CAN bus line
|
Ignition switch on (IG)
|
Pulse generation (see waveform 3)
|
D33-12 (CANL) - D33-14 (GND)
|
W - W-B
|
Lo-level CAN bus line
|
Ignition switch on (IG)
|
Pulse generation (see waveform 4)
|
D33-13 (SG-2) - Body ground
|
SB - Body ground
|
Ground for pressure sensor
|
Always
|
Below 1 V
|
D33-14 (GND) - Body ground
|
W-B - Body ground
|
Ground for main power supply
|
Always
|
Below 1 V
|
D33-20 (MGC) - D33-14 (GND)
|
V - W-B
|
Air conditioning compressor magnetic clutch operation signal
|
Engine idling
|
Below 1 V
|
Blower switch LO
|
Air Conditioning switch ON
|
D33-21 (B) - D33-14 (GND)
|
B - W-B
|
Power source (Back-up)
|
Always
|
11 to 14 V
|
D33-22 (PTC2) - Body ground (*1)
|
G - Body ground
|
PTC NO. 2 heater relay operation signal
|
Engine idling
|
Below 1 V → 11 to 14 V
|
Set temperature: MAX HOT
|
Engine coolant temperature: Below 65°C (149°F)
|
Ambient temperature: Below 10°C (50°F)
|
Blower switch OFF → LO
|
D33-23 (BLW) - D33-14 (GND)
|
R - W-B
|
Blower motor control signal
|
Ignition switch on (IG)
|
Pulse generation (see waveform 2)
|
Blower switch LO
|
D33-25 (ALT) - Body ground (*1)
|
SB - Body ground
|
Generator signal
|
Engine idling
|
Pulse generation
|
D33-27 (HLS) - Body ground (*1)
|
V - Body ground
|
Headlight signal
|
Engine idling
|
Below 1 V
|
Headlight switch ON
|
D33-29 (TR) - D33-34 (SG-4)
|
BR- B
|
Room temperature sensor signal (for Front)
|
Ignition switch on (IG)
|
1.8 to 2.2 V
|
Vehicle interior temperature: 25°C (77°F)
|
D33-32 (TSP) - D33-14 (GND)
|
GR - W-B
|
Front passenger side solar sensor signal
|
Ignition switch on (IG)
|
0.8 to 4.3 V
|
Solar sensor subject to electric light
|
D33-33 (TSD) - D33-14 (GND)
|
O - W-B
|
Driver side solar sensor signal
|
Ignition switch on (IG)
|
0.8 to 4.3 V
|
Solar sensor subject to electric light
|
D33-35 (SG-4) - Body ground
|
LG - Body ground
|
Ground for room temperature sensor (for Front)
|
Always
|
Below 1 V
|
D33-37 (LIN1) - D33-14 (GND)
|
R - W-B
|
LIN communication signal
|
Ignition switch on (IG)
|
Pulse generation
|
D33-38 (RDEF) - D33-14 (GND)
|
W - W-B
|
Rear defogger switch signal
|
Ignition switch on (IG) Rear defogger switch OFF
|
11 to 14 V
|
D33-38 (RDEF) - D33-14 (GND)
|
W - W-B
|
Rear defogger switch signal
|
Ignition switch on (IG) Rear defogger switch ON
|
Below 1 V
|
D34-1 (RBUS) - D34-21 (RBUG) (*2)
|
R - V
|
BUS IC control signal (for Rear)
|
Ignition switch on (IG)
|
Pulse generation
|
D34-4 (TEC) - D34-19 (SGND) (*2)
|
B - GR
|
Evaporator temperature sensor signal (for Rear)
|
Ignition switch on (IG)
|
1.4 to 1.8 V
|
Evaporator temperature: 15°C (59°F)
|
D34-7 (SG-6) - Body ground (*3)
|
W - Body ground
|
Ground for room temperature sensor signal (for Rear)
|
Always
|
Below 1 V
|
D34-13 (RLIN) - D34-20 (GND2) (*2)
|
B - SB
|
LIN communication signal (for Rear)
|
Ignition switch on (IG)
|
Pulse generation
|
D34-17 (TR) - D34-7 (SG-6) (*3)
|
BR - W
|
Room temperature sensor signal (for Rear)
|
Ignition switch on (IG)
|
1.8 to 2.2 V
|
Vehicle interior temperature: 25°C (77°F)
|
D34-19 (SGND) - Body ground (*2)
|
GR - Body ground
|
Ground for evaporator temperature sensor signal (for Rear)
|
Always
|
Below 1 V
|
D34-20 (GND2) - Body ground (*2)
|
SB - Body ground
|
Ground for power supply
|
Always
|
Below 1 V
|
D34-21 (RBUG) - Body ground (*2)
|
V - Body ground
|
Ground for BUS IC (for Rear)
|
Always
|
Below 1 V
|
D34-22 (BLWH) - D34-20 (GND2) (*2)
|
G - SB
|
Blower motor control signal (for Rear)
|
Ignition switch on (IG)
|
Pulse generation
|
Blower switch LO
|
D34-23 (RBBU) - D34-21 (RBUG) (*2)
|
Y - V
|
Power supply for BUS IC (for Rear)
|
Ignition switch on (IG)
|
11 to 14 V
|
D34-24 (+B2) - D34-20 (GND2) (*2)
|
LG - SB
|
Power source (Back-up) (for Rear)
|
Always
|
11 to 14 V
|
z17-2 (BUS G) - Body ground
|
-
|
Ground for BUS IC
|
Always
|
Below 1 V
|
z17-3 (BUS) - a1-2 (BUS G)
|
-
|
BUS IC control signal
|
Ignition switch on (IG)
|
Pulse generation
|
z17-4 (B BUS) - a1-2 (BUS G)
|
-
|
Power supply for BUS IC
|
Ignition switch on (IG)
|
11 to 14 V
|
z17-5 (SG) - Body ground
|
-
|
Ground for evaporator temperature sensor
|
Always
|
Below 1 V
|
z17-6 (TE) - z17-5 (SG)
|
-
|
Evaporator temperature sensor signal (for Front)
|
Ignition switch on (IG)
|
1.4 to 1.8 V
|
Evaporator temperature: 15°C (59°F)
|