2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

TERMINALS OF ECU

System information · Vehicles built from Jul 2010

Versions by build date: May 2007 – Jun 2010 from Jul 2010


CHECK AIR CONDITIONING AMPLIFIER
E127561E04
  1. Measure the voltage of the connectors.

    HINT:
    Check from the rear of the connector while it is connected to the air conditioning amplifier.

    Tester Connection
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    D33-1 (IG+) - D33-14 (GND)
    GR - W-B
    Power source (IG)
    Ignition switch on (IG)
    11 to 14 V
    D33-2 (SOL+) - D33-14 (GND)
    L - W-B
    A/C compressor operation signal
    Engine idling
    Pulse generation
    (see waveform 1)
    Blower switch LO
    A/C switch ON
    D33-3 (PTC1) - Body ground (*1)
    P - Body ground
    PTC NO. 1 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D33-4 (PTC3) - Body ground (*1)
    W - Body ground
    PTC NO. 3 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D33-5 (TAM) - D33-14 (GND)
    GR - W-B
    Ambient temperature sensor signal
    Ignition switch on (IG)
    1.8 to 2.2 V
    Ambient temperature: 25°C (77°F)
    D33-7 (FLOQ) - D33-13 (SG-2)
    G - SB
    A/C flow sensor signal
    Ignition switch on (IG)
    0.3 to 4.7 V
    D33-7 (FLOQ) - D33-13 (SG-2)
    G - SB
    A/C flow sensor signal
    Ignition switch on (IG)
    Below 1 V
    D33-8 (LOCK) - D33-14 (GND)
    V - W-B
    Air compressor lock sensor signal
    Engine idling
    Pulse generation
    (see waveform 5)
    A/C switch ON
    Blower switch LO
    D33-9 (PRE) - D33-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Normal
    0.76 to 4.74 V
    D33-9 (PRE) - D33-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2, 28 psi])
    0.5 to 4.83 V
    D33-9 (PRE) - D33-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Abnormal (more than 3.14 MPa [32 kgf/cm2, 455 psi])
    4.74 V or higher
    D33-10 (S5-3) - D33-14 (GND)
    BE - W-B
    Power supply for pressure sensor
    Ignition switch on (IG)
    4.5 to 5.5 V
    D33-11 (CANH) - D33-14 (GND)
    LG - W-B (*3)
    P - W-B (*4)
    Hi-level CAN bus line
    Ignition switch on (IG)
    Pulse generation
    (see waveform 3)
    D33-12 (CANL) - D33-14 (GND)
    W - W-B
    Lo-level CAN bus line
    Ignition switch on (IG)
    Pulse generation
    (see waveform 4)
    D33-13 (SG-2) - Body ground
    SB - Body ground
    Ground for pressure sensor
    Always
    Below 1 V
    D33-14 (GND) - Body ground
    W-B - Body ground
    Ground for main power supply
    Always
    Below 1 V
    D33-20 (MGC) - D33-14 (GND)
    V - W-B
    A/C compressor magnetic clutch operation signal
    Engine idling
    Below 1 V
    Blower switch LO
    A/C switch ON
    D33-21 (B) - D33-14 (GND)
    LG - W-B
    Power source (Back-up)
    Always
    11 to 14 V
    D33-22 (PTC2) - Body ground (*1)
    G - Body ground
    PTC NO. 2 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D33-23 (BLW) - D33-14 (GND)
    R - W-B
    Blower motor control signal
    Ignition switch on (IG)
    Pulse generation
    (see waveform 2)
    Blower switch LO
    D33-25 (ALT) - Body ground (*1)
    SB - Body ground
    Generator signal
    Engine idling
    Pulse generation
    D33-30 (S5-1) - D33-13 (SG-2)
    Y - SB
    Power supply for A/C flow sensor
    Ignition switch on (IG)
    4.5 to 5.5 V
    D33-30 (S5-1) - D33-13 (SG-2)
    Y - SB
    Power supply for A/C flow sensor
    Ignition switch on (IG)
    Below 1 V
    D33-37 (LIN1) - D33-14 (GND)
    R - W-B
    LIN communication signal
    Ignition switch on (IG)
    Pulse generation
    D33-38 (RDEF) - D33-14 (GND)
    W - W-B
    Rear defogger switch signal
    Ignition switch on (IG)
    Rear defogger switch OFF
    11 to 14 V
    D34-1 (RBUS) - D34-21 (RBUG) (*2)
    R - V
    BUS IC control signal (for Rear)
    Ignition switch on (IG)
    Pulse generation
    D34-4 (TEC) - D34-19 (SGND) (*2)
    B - GR
    Evaporator temperature sensor signal (for Rear)
    Ignition seitch on (IG)
    1.4 to 1.8 V
    Evaporator temperature: 15°C (59°F)
    D34-13 (RLIN) - D34-20 (GND2) (*2)
    B - W-B
    LIN communication signal (for Rear)
    Ignition switch on (IG)
    Pulse generation
    D34-19 (SGND) - Body ground (*2)
    GR - Body ground
    Ground for evaporator temperature sensor signal (for Rear)
    Always
    Below 1 V
    D34-20 (GND2) - Body ground (*2)
    W-B - Body ground
    Ground for power supply
    Always
    Below 1 V
    D34-21 (RBUG) - Body ground (*2)
    V - Body ground
    Ground for BUS IC (for Rear)
    Always
    Below 1 V
    D34-22 (BLWH) - D34-20 (GND2) (*2)
    G - W-B
    Blower motor control signal (for Rear)
    Ignition switch on (IG)
    Pulse generation
    Blower switch LO
    D34-23 (RBBU) - D34-21 (RBUG) (*2)
    Y - V
    Power supply for BUS IC (for Rear)
    Ignition switch on (IG)
    11 to 14 V
    D34-24 (+B2) - D34-20 (GND2) (*2)
    LG - W-B
    Power source (Back-up) (for Rear)
    Always
    11 to 14 V
    z17-2 (BUS G) - Body ground
    -
    Ground for BUS IC
    Always
    Below 1 V
    z17-3 (BUS) - z17-2 (BUS G)
    -
    BUS IC control signal
    Ignition switch on (IG)
    Pulse generation
    z17-4 (B BUS) - z17-2 (BUS G)
    -
    Power supply for BUS IC
    Ignition switch on (IG)
    11 to 14 V
    z17-5 (SG) - Body ground
    -
    Ground for evaporator temperature sensor
    Always
    Below 1 V
    z17-6 (TE) - z17-5 (SG)
    -
    Evaporator temperature sensor signal
    Ignition switch on (IG)
    1.4 to 1.8 V
    Evaporator temperature: 15°C (59°F)
    1. *1: w/ PTC Heater
    2. *2: w/ Rear Air Conditioning
    3. *3: for LHD
    4. *4: for RHD

  2. E074977E11
    Using an oscilloscope, check waveform 1.
    Compressor and pulley operation signal 
    Item
    Content
    Tester Connection
    D33-2 (SOL+) - D33-14 (GND)
    Tool Setting
    5 V/DIV., 500 μsec./DIV.
    Condition
    Engine idling, Blower switch LO, A/C switch ON

  3. E103396E05
    Using an oscilloscope, check waveform 2.
    Blower motor control signal 
    Item
    Content
    Tester Connection
    D33-23 (BLW) - D33-14 (GND)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Ignition switch on (IG), Blower switch LO

    HINT:
    When the blower level is increased, the duty ratio changes accordingly.

  4. A086154E10
    Using an oscilloscope, check waveform 3.
    CAN communication signal 
    Item
    Content
    Tester Connection
    D33-11 (CANH) - D33-14 (GND)
    Tool Setting
    1 V/DIV., 10 μsec./DIV.
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.

  5. A086155E11
    Using an oscilloscope, check waveform 4.
    CAN communication signal 
    Item
    Content
    Tester Connection
    D33-12 (CANL) - D33-14 (GND)
    Tool Setting
    1 V/DIV., 10 μsec./DIV.
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.

  6. E147961E01
    Using an oscilloscope, check waveform 5.
    A/C compressor lock sensor signal 
    Item
    Content
    Tester Connection
    D33-8 (LOCK) - D33-14 (GND)
    Tool Setting
    200 mV/DIV., 10 ms./DIV.
    Condition
    Engine is running
    Blower switch: LO
    A/C switch: ON

    HINT:
    The waveform varies depending on the engine speed.


CHECK FRONT AIR CONDITIONING CONTROL
E152670E04
  1. Measure the voltage of the connectors.

    Tester Connection
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    E8-2 (IG+) - E8-10 (GND)
    V - W-B
    Power source (IG)
    Ignition switch on (IG)
    11 to 14 V
    E8-5 (LIN1) - E8-10 (GND)
    R - W-B
    LIN communication signal
    LIN switch on (IG)
    Pulse generation
    E8-10 (GND) - Body ground
    W-B - Body ground
    Ground for front air conditioning control
    Always
    Below 1 V


CHECK REAR AIR CONDITIONING CONTROL (for Rear Air Conditioning)
E152670E02
  1. Measure the voltage of the connectors.

    Tester Connection
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    R1-2 (IG+) - R1-10 (E)
    V - W-B
    Power source (IG)
    Ignition switch on (IG)
    11 to 14 V
    R1-5 (MPX-) - R1-10 (E)
    B - W-B
    LIN communication signal
    LIN switch on (IG)
    Pulse generation
    R1-10 (E) - Body ground
    W-B - Body ground
    Ground for front air conditioning control
    Always
    Below 1 V

← TERMINALS OF ECU (May 2007 – Jun 2010)DIAGNOSIS SYSTEM (from May 2007) →