The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature.
Valve opening temperature:
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the thermostat.
Check the valve lift.
Valve lift:
10 mm (0.39 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at low temperatures (below 40°C (104°F)). If it is not fully closed, replace the thermostat.