2007-2013 Highlander Kluger · Service Manual ENGINE

B2273 Ignition 2 Monitor Malfunction

Diagnostic trouble codes · Vehicles built from Jul 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

This DTC is output if there is a problem in the IG2D output circuit, which is from the inside of the main body ECU to the IG2 relay.

HINT:
If the main body ECU is replaced with a new one while the negative (-) battery terminal is connected, the power source mode will be in IG-ON mode. When the battery is removed and reinstalled, the power source mode that was selected when the battery was removed is restored.
After the main body ECU is replaced, perform the registration procedure for the engine immobiliser system.

DTC No.
DTC Detection Condition
Trouble Area
B2273
IG2 relay actuation circuit inside main body ECU or other related circuit is malfunctioning
  1. Main body ECU (Instrument panel junction block)
  2. IG2 relay
  3. Wire harness or connector

WIRING DIAGRAM

B177336E03

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the engine switch on (IG) and turn the intelligent tester main switch on.

  1. Read the Data List according to the displays on the tester.

    HINT:
    When using the intelligent tester with the engine switch off, turn on and off any of the door courtesy light switches repeatedly at 1.5 second intervals or less until communication between the tester and vehicle starts.

    Body: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    IG2 Relay Mon1
    Status of IG2 relay monitor (outer) / ON or OFF
    ON: Engine switch on (IG) (IG2 relay is ON)
    OFF: Engine switch off (IG2 relay is OFF)
    -

    OK:
    "ON" (Engine switch on (IG)) appears on the screen.



NG
Go to step 4
OK


2. CHECK ENGINE SWITCH CONDITION
  1. Check the power source mode changes.

    1. When the key is inside the vehicle and the shift lever is in the P position, check that pressing the engine switch causes the power source mode to change as follows:

      OK:
      off → on (ACC) → on (IG) → off



NG
GO TO OTHER FLOW CHART (Click here)
OK


3. CHECK DTC OUTPUT
  1. Delete the DTCs (Click here).

  1. Check for DTCs again.

    OK:
    No DTC is output.



NG
REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)
OK

USE SYMPTOM METHOD TO CHECK (Click here)

4. INSPECT RELAY (IG2 RELAY)

  1. B016200E23
    Remove the IG2 relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    When battery voltage is not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    When battery voltage is applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE IG2 RELAY
OK


5. CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK - MAIN BODY ECU AND BODY GROUND)

  1. Disconnect the D6 ECU connector.B177337E02

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Engine room relay block IG2 relay terminal 1 - D6-11 (IG2D)
    Always
    Below 1 Ω
    D6-11 (IG2D) - Body ground
    Always
    10 kΩ or higher
    Engine room relay block IG2 relay terminal 2 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ENGINE ROOM RELAY BLOCK - MAIN BODY ECU AND BODY GROUND)
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)


← B2273 Ignition 2 Monitor Malfunction (Aug 2008 – Jun 2010)B2274 ACC Monitor Malfunction (May 2007 – Jul 2008) →