2007-2013 Highlander Kluger · Service Manual RESTRAINTS

B1830/57 Short in Curtain Shield Squib RH Circuit

Diagnostic trouble codes · Vehicles built from Jul 2010

Also covers:

DESCRIPTION

The curtain shield squib RH circuit consists of the center airbag sensor assembly and curtain shield airbag assembly RH.
The center airbag sensor assembly uses this circuit to deploy the airbag when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH circuit.
DTC No.
DTC Detection Condition
Trouble Area
B1830/57
  1. The center airbag sensor assembly receives a line short circuit signal in the curtain shield squib RH circuit during primary check.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor assembly malfunction
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1831/57
  1. The center airbag sensor assembly receives an open circuit signal in the curtain shield squib RH circuit.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor assembly malfunction
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1832/57
  1. The center airbag sensor assembly receives a short circuit to ground signal in the curtain shield squib RH circuit.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor assembly malfunction
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1833/57
  1. The center airbag sensor assembly receives a short circuit to B+ signal in the curtain shield squib RH circuit.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor assembly malfunction
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly

WIRING DIAGRAM

C198980E56

INSPECTION PROCEDURE

HINT:
  1. Perform the simulation method by selecting check mode (Signal Check) using the intelligent tester (Click here).
  2. After selecting check mode (Signal Check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).


1. CHECK CONNECTORS

  1. C165140E53
    Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Check that the connectors are properly connected to the curtain shield airbag assembly RH and center airbag sensor assembly.

    OK:
    The connectors are properly connected.

    HINT:
    If the connectors are not connected securely, reconnect the connectors and proceed to the next inspection.

  1. Disconnect the connectors from the curtain shield airbag assembly RH and center airbag sensor assembly.

  1. Check that the terminals of the connectors are not damaged.

    OK:
    The terminals are not deformed or damaged.

  1. Check that the floor wire connector (on the curtain shield airbag assembly RH side) is not damaged.

    OK:
    The lock button is not disengaged, and the claw of the lock is not deformed or damaged.

  1. Check that the short spring for the floor wire with the activation prevention mechanism is not deformed or damaged.

    OK:
    The short spring is not deformed or damaged.



NG
REPLACE FLOOR WIRE
OK


2. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH (CURTAIN SHIELD SQUIB RH)

  1. C210792E13
    Connect the connector to the center airbag sensor assembly.

  1. Connect SST (resistance 2.1 Ω) to connector C.

    CAUTION:
    Never connect the tester to the curtain shield airbag assembly RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the ignition switch on (IG), and wait for at least 60 seconds.

  1. Clear the DTCs stored in the memory (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch on (IG), and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1830, B1831, B1832, B1833 or 57 is not output.

    HINT:
    Codes other than DTCs B1830, B1831, B1832, B1833 and 57 may be output at this time, but they are not related to this check.



NG
Go to step 3
OK

REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH (Click here)

3. CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT)

  1. C157580E27
    Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect SST from connector C.

  1. Disconnect the floor wire from the center airbag sensor assembly.

  1. Check for a short to B+ in the circuit.

    1. Connect the cable to the negative (-) battery terminal.

    2. Turn the ignition switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      N8-1 (ICR+) - Body ground
      Ignition switch on (IG)
      Below 1 V
      N8-2 (ICR-) - Body ground
      Ignition switch on (IG)
      Below 1 V

  1. Check for an open in the circuit.

    1. Turn the ignition switch off.

    2. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      N8-1 (ICR+) - N8-2 (ICR-)
      Always
      Below 1 Ω

  1. Check for a short to ground in the circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      N8-1 (ICR+) - Body ground
      Always
      1 MΩ or higher
      N8-2 (ICR-) - Body ground
      Always
      1 MΩ or higher

  1. Check for a short in the circuit.

    1. Release the activation prevention mechanism built into connector B (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      N8-1 (ICR+) - N8-2 (ICR-)
      Always
      1 MΩ or higher



NG
REPLACE FLOOR WIRE
OK


4. CHECK CENTER AIRBAG SENSOR ASSEMBLY

  1. C170976E10
    Restore the released activation prevention mechanism of connector B to the original condition.

  1. Connect the connectors to the curtain shield airbag assembly RH and center airbag sensor assembly.

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the ignition switch on (IG), and wait for at least 60 seconds.

  1. Clear the DTCs stored in the memory (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch on (IG), and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1830, B1831, B1832, B1833 or 57 is not output.

    HINT:
    Codes other than DTCs B1830, B1831, B1832, B1833 and 57 may be output at this time, but they are not related to this check.



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)
OK

USE SIMULATION METHOD TO CHECK (Click here)


← B1825/56 Short in Front Passenger Side - Side Squib Circuit (+ B1826/56, B1827/56, B1828/56) (Aug 2008 – Jun 2010)B1830/57 Short in Driver Side Curtain Shield Squib Circuit (+ B1831/57, B1832/57, B1833/57) (May 2007 – Jul 2008) →