2007-2013 Highlander Kluger · Service Manual BODY ELECTRICAL

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT FRONT DOOR LOCK ASSEMBLY (for Driver Side)

  1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

    B164413E01

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → 4 (L)
    Battery negative (-) → 1 (UL)
    Locked
    Battery positive (+) → 1 (UL)
    Battery negative (-) → 4 (L)
    Unlocked

  1. Measure the resistance of the door lock position switch.

    Standard resistance:
    Tester Connection
    Measurement Condition
    Door Lock Condition
    Specified Condition
    7 - 8
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 1
    Locked
    10 kΩ or higher
    7 - 8
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 4
    Unlocked
    Below 1 Ω

  1. Measure the resistance of the door key lock and unlock switch operation.

    1. B164389E07
      for LHD models:

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      7 - 9
      Locked
      Below 1 Ω
      7 - 9
      7 - 10
      OFF (Free)
      10 kΩ or higher
      7 - 10
      Unlocked
      Below 1 Ω

      If the result is not as specified, replace the door lock assembly.

    2. B178840E01
      for RHD models:

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      8 - 6
      Locked
      Below 1 Ω
      8 - 6
      8 - 5
      OFF (Free)
      10 kΩ or higher
      8 - 5
      Unlocked
      Below 1 Ω

      If the result is not as specified, replace the door lock assembly.


INSPECT FRONT DOOR LOCK ASSEMBLY (for Front Passenger Side)

  1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

    B164413E02

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 1
    Locked
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 4
    Unlocked

    If the result is not as specified, replace the door lock assembly.

  1. Measure the resistance of the door lock position switch.

    Standard resistance:
    Tester Connection
    Measurement Condition
    Door Lock Condition
    Specified Condition
    7 - 8
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 1
    Locked
    10 kΩ or higher
    7 - 8
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 4
    Unlocked
    Below 1Ω

    If the result is not as specified, replace the door lock assembly.

← REMOVAL (from Jul 2010)INSTALLATION (May 2007 – Jul 2008) →