INSPECT AMBIENT TEMPERATURE SENSOR

  1. E114516E16
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A7-1 - A7-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    A7-1 - A7-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    A7-1 - A7-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    A7-1 - A7-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    A7-1 - A7-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    A7-1 - A7-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    A7-1 - A7-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    A7-1 - A7-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    A7-1 - A7-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    A7-1 - A7-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    A7-1 - A7-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    If the resistance is not as specified, replace the ambient temperature sensor.

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).