INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Standard) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
Q2-2 - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
Q2-1 - Body ground
Always
11 to 14 V
| INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Independent Type) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
- LH Side:
Tester Connection
Condition
Specified Condition
Q4-3 - Body ground
Always
Below 1 Ω
- RH Side:
Tester Connection
Condition
Specified Condition
Q3-3 - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
- LH Side:
Tester Connection
Condition
Specified Condition
Q4-2 - Body ground
Always
11 to 14 V
- RH Side:
Tester Connection
Condition
Specified Condition
Q3-2 - Body ground
Always
11 to 14 V