2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT ROOM TEMPERATURE SENSOR
  1. Remove the rear room temperature sensor (Click here).

  1. Disconnect the connector from the rear room temperature sensor.

  1. E152647E07
    Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N12-1 (+)- N12-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    N12-1 (+)- N12-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    N12-1 (+)- N12-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    N12-1 (+)- N12-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    N12-1 (+)- N12-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    N12-1 (+)- N12-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    N12-1 (+)- N12-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    N12-1 (+)- N12-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    N12-1 (+)- N12-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    N12-1 (+)- N12-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    N12-1 (+)- N12-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).
    If the resistance value is not as specified, replace the sensor.

← REMOVAL (from May 2007)INSTALLATION (from May 2007) →