2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT EVAPORATOR TEMPERATURE SENSOR

E127592E04
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N11-7 (-) - N11-8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    N11-7 (-) - N11-8 (+)
    -5°C (23°F)
    5.65 to 6.95 kΩ
    N11-7 (-) - N11-8 (+)
    0°C (32°F)
    4.40 to 5.35 kΩ
    N11-7 (-) - N11-8 (+)
    5°C (41°F)
    3.40 to 4.15 kΩ
    N11-7 (-) - N11-8 (+)
    10°C (50°F)
    2.70 to 3.25 kΩ
    N11-7 (-) - N11-8 (+)
    15°C (59°F)
    2.14 to 2.58 kΩ
    N11-7 (-) - N11-8 (+)
    20°C (68°F)
    1.71 to 2.05 kΩ
    N11-7 (-) - N11-8 (+)
    25°C (77°F)
    1.38 to 1.64 kΩ
    N11-7 (-) - N11-8 (+)
    6 - 5
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    If the resistance value is not as specified, replace the sensor.