2007-2013 Highlander Kluger · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from May 2007


THERMOSTAT:
Condition
Specified Condition
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 mm (0.39 in.) or more at 95°C (203°F)


COOLING FAN MOTOR:
Item
Condition
Specified Condition
No. 1 cooling fan motor
12 V
14.6 to 18.7 A
No. 2 cooling fan motor
12 V
14.6 to 18.7 A


COOLING FAN ECU:
Item
Condition
Specified Condition
Cooling fan ECU
Ignition switch on (IG)
11 to 14 V


COOLING FAN RELAY:
Item
Tester Connection
Specified Condition
Fan main relay
3 - 5
10 kΩor higher
(battery volltage is not applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(apply battery voltage between terminals 1 and 2)


RADIATOR:
Item
Condition
Specified Condition
Radiator cap
Standard value
(for brand-new cap)
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value
(for used cap)
78.5 kPa (0.8 kgf/cm2, 11.4 psi)

← TORQUE SPECIFICATIONS (from May 2007)TORQUE SPECIFICATIONS (May 2007 – Jul 2013) →