2007-2013 Highlander Kluger · Service Manual TRANSMISSION

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT SHIFT SOLENOID VALVE SL3

  1. G020767E90
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLT

  1. G020767E92
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE S4

  1. C113971E07
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S4) - Solenoid Body (S4)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SR

  1. C113977E07
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (SR) - Solenoid Body (SR)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE DSL

  1. C113970E11
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (DSL) - Solenoid Body (DSL)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL2

  1. G020767E89
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL1

  1. G020767E88
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.

← DISASSEMBLY (from May 2007)REASSEMBLY (from May 2007) →