B1417/17 Rear Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The rear air conditioning harness (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the rear air conditioning harness (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the rear air conditioning harness (rear evaporator temperature sensor) and reads voltage changes as changes in the resistance of the rear air conditioning harness (rear evaporator temperature sensor). This sensor is used for frost prevention.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1417/17 |
Open or short in rear air conditioning harness circuit (rear evaporator temperature sensor) |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (R-EVAP TEMP SEN) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
R-Evap Temp Sen
Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature is displayed
Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.55°C (139.19°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from PROBLEM SYMPTOMS TABLE)
B
OK (Checking from DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT REAR AIR CONDITIONING HARNESS (REAR EVAPORATOR TEMPERATURE SENSOR) |
Remove the rear air conditioning harness.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
N11-7 (-) - N11-8 (+)
-10°C (14°F)
7.30 to 9.10 kΩ
N11-7 (-) - N11-8 (+)
-5°C (23°F)
5.65 to 6.95 kΩ
N11-7 (-) - N11-8 (+)
0°C (32°F)
4.40 to 5.35 kΩ
N11-7 (-) - N11-8 (+)
5°C (41°F)
3.40 to 4.15 kΩ
N11-7 (-) - N11-8 (+)
10°C (50°F)
2.70 to 3.25 kΩ
N11-7 (-) - N11-8 (+)
15°C (59°F)
2.14 to 2.58 kΩ
N11-7 (-) - N11-8 (+)
20°C (68°F)
1.71 to 2.05 kΩ
N11-7 (-) - N11-8 (+)
25°C (77°F)
1.38 to 1.64 kΩ
N11-7 (-) - N11-8 (+)
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
- When measuring, the thermistor temperature must be the same as the ambient temperature.
- Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (REAR AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER) |
Disconnect the N11 rear air conditioning harness connector.

Disconnect the D34 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
N11-8 (+) - D34-4 (TEC)
Always
Below 1 Ω
N11-7 (-) - D34-19 (SGND)
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||