INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT VACUUM SWITCHING VALVE ASSEMBLY |
Inspect VSV operation.

Using an ohmmeter, measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
37 to 44 Ω
Inspect the VSV for a short to ground.
Using an ohmmeter, measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - Body ground
20°C (68°F)
10 kΩ or higher
2 - Body ground
20°C (68°F)
10 kΩ or higher
Inspect VSV operation.

Check that air flows from port E to the filter.
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If operation is not as specified, replace the VSV.