2007-2013 Highlander Kluger · Service Manual ENGINE

ON-VEHICLE INSPECTION

Inspection · Vehicles built from May 2007


INSPECT AIR CLEANER CAP SUB-ASSEMBLY

A170446E01
  1. Check that air flows from port B to port A.

  1. Apply 60 kPa (450 mmHg, 18 in. Hg) of vacuum to port B. Check that there is no change in vacuum after one minute.