INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT SOLAR SENSOR |
Remove the A/C solar sensor with the connector still connected.

Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.
Measure the voltage according to the value(s) in the table below.
- Standard voltage
Tester Connection
Condition
Specified Condition
F1-1 (TSR) - F1-3 (CLTE)
Sensor is subjected to electric light
0.8 to 4.3 V
F1-1 (TSR) - F1-3 (CLTE)
Sensor is covered with a cloth
Below 0.8 V
F1-2 (TSR) - F1-3 (CLTE)
Sensor is subjected to electric light
0.8 to 4.3 V
F1-2 (TSR) - F1-3 (CLTE)
Sensor is covered with a cloth
Below 0.8 V
- NOTICE:
- The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and negative (-) lead to terminal 1 of the solar sensor.
- While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
- The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and negative (-) lead to terminal 1 of the solar sensor.
- HINT:
- Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
- As the inspection light is moved away from the sensor, the voltage decreases.
- Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
- Standard voltage