2007-2013 Highlander Kluger · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT HEATED OXYGEN SENSOR

  1. A141063E08
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1 
    Tester Connection
    Condition
    Specified Condition
    2 (HT1B) - 1 (+B)
    20°C (68°F)
    11 to 16 Ω
    2 (HT1B) - 3 (E2)
    Always
    10 kΩ or higher
    Bank 2 
    Tester Connection
    Condition
    Specified Condition
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    Always
    10 kΩ or higher

    If the resistance is not as specified, replace the heated oxygen sensor.

← REMOVAL (from Jul 2010)INSTALLATION (May 2007 – Jul 2008) →