Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0230    Fuel Pump Primary Circuit

for Preparation Click here


DESCRIPTION

  1. This DTC is designed to detect a malfunction in the fuel pump (FUEL PMP) relay circuit. When the system is normal, the battery voltage is applied to FPR terminal of the ECM while the FUEL PMP relay is turned OFF. If the battery voltage is not applied to the FPR terminal while the FUEL PMP relay is OFF, the ECM interprets this as a malfunction. The ECM then illuminates the MIL and sets a DTC.
  2. The FUEL PMP relay switches the fuel pump speed according to the engine conditions. The fuel pump operates when the ECM receives the starter-operating signal (STA) and crankshaft-rotating signal (NE). The FUEL relay is turned ON while the engine is idling or operating at low load. This causes current to flow through the fuel pump resistor to the fuel pump. The fuel pump then operates at low speed. The FUEL relay is turned OFF while the engine is cranking or operating at high load. The fuel pump then operates at normal speed.

DTC No.
DTC Detection Condition
Trouble Area
P0230
Open or short in FUEL PUMP relay circuit (1 trip detection logic)
  1. Open or short in FUEL PUMP relay circuit
  2. FUEL PMP relay
  3. ECM

WIRING DIAGRAM


A172702E02


A172703E02

This troubleshooting procedure is based on the premise that the engine is started. If the engine is not started, proceed to the problem symptoms table (Click here).

INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG) and turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Active the Fuel Pump Speed Control.

  1. Check the operation of the relay while operating it using the tester.

    OK:
    Operating noise can be heard from the relay.



NG
Go to step 2
OK

REPLACE ECM (Click here)  

2.INSPECT RELAY (FUEL PMP RELAY)


    A137690
  1. Remove the FUEL PMP relay from the engine room junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Always
    Approximately 111 Ω

  1. Reinstall the FUEL PMP relay.



NG
REPLACE RELAY (FUEL PMP RELAY)
OK


3.CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - ECM)


    A168251E03
  1. Remove the FUEL PMP relay from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    FUEL PMP relay terminal 1 - B3-30 (FPR)
    Always
    Below 1 Ω
    FUEL PMP relay terminal 1 or B3-30 (FPR) - Body Ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reinstall the FUEL PMP relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PMP RELAY - ECM)
OK

REPLACE ECM (Click here)