SFI SYSTEM > Fuel Pump Control Circuit |



| 1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE C/OPN RELAY) |
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG), and turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
Check the relay operation while operating it using the tester.
|
| ||||
| OK | |
| 2.INSPECT TERMINAL VOLTAGE (FUEL PMP RELAY TERMINAL) |
![]() |
Remove the FUEL PMP relay from the engine room relay block.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| FUEL PMP relay terminal 2 - Body ground | Ignition switch on (IG) | 9 to 14 V |
| FUEL PMP relay terminal 3 - Body ground | Ignition switch on (IG) | 9 to 14 V |
Reinstall the FUEL PMP relay.
|
| ||||
| OK | |
| 3.INSPECT RELAY (FUEL PMP RELAY) |
![]() |
Remove the FUEL PMP relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 4 | When no battery voltage is applied terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | When no battery voltage is applied terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | When battery voltage is applied terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | When battery voltage is applied terminals 1 and 2 | Below 1 Ω |
Reinstall the FUEL PMP relay.
|
| ||||
| OK | |
| 4.INSPECT FUEL PUMP RESISTOR |
![]() |
Disconnect the fuel pump resistor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 0.30 to 0.34 Ω |
Reconnect the fuel pump resistor connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (FUEL PUMP - FUEL PMP RELAY) |
![]() |
Check the wire harness between the FUEL PMP relay and fuel pump.
Remove the fuel pump relay from the engine room relay block.
Disconnect the fuel pump connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| FUEL PMP relay terminal 4 - O9-4 | Always | Below 1 Ω |
| FUEL PMP relay terminal 4 or O9-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (FUEL PUMP RELAY - FUEL PUMP RESISTOR) |
![]() |
Disconnect the fuel pump resistor connector.
Remove the fuel pump relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| FUEL PMP relay terminal (5) - A35-1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| FUEL PMP relay terminal (5) or A35-1 - Body ground | Always | 10 kΩ or higher |
Reconnect the fuel pump resistor connector.
Reinstall the fuel pump relay.
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (FUEL PUMP RESISTOR - FUEL PUMP) |
![]() |
Disconnect the fuel pump resistor connector.
Disconnect the fuel pump connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A35-2 - O9-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A35-2 or O9-4 - Body ground | Always | 10 kΩ or higher |
Reconnect the fuel pump resistor connector.
Reconnect the fuel pump connector.
|
| ||||
| OK | |
| 8.INSPECT FUEL PUMP |
![]() |
Inspect the fuel pump.
Measure the resistance according to the value(s) in the table below.
| Tester Connections | Condition | Specified Condition |
| 4 - 5 | 20°C (68°F) | 0.2 to 0.3 Ω |
Apply battery voltage to both terminals 4(+) and 5(-). Check that the pump operates.
|
| ||||
| OK | ||
| ||
| 9.CHECK ECM POWER SOURCE CIRCUIT |
|
| ||||
| OK | |
| 10.INSPECT ENGINE ROOM JUNCTION BLOCK ASSEMBLY (C/OPN RELAY) |
Inspect the C/OPN relay (Click here).
|
| ||||
| OK | |
| 11.INSPECT ECM (FC VOLTAGE) |
![]() |
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D35-10 (FC) - B3-1 (E1) | Ignition switch on (IG) | 9 to 14 V |
|
| ||||
| OK | ||
| ||
| 12.CHECK HARNESS AND CONNECTOR (ECM - C/OPN RELAY) |
![]() |
Disconnect the ECM connector.
Remove the engine room junction block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D35-10 (FC) - 2D-12 (C/OPN relay terminal) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| D35-10 (FC) or 2D-12 (C/OPN relay terminal) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the engine room junction block.
|
| ||||
| OK | ||
| ||