Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM

POWER WINDOW CONTROL SYSTEM > FAIL-SAFE CHART

for Preparation Click here



POWER WINDOW OPERATION IN FAIL-SAFE MODE

HINT:
If the pulse sensor built into the power window regulator motor (on the driver side) malfunctions, the power window control system enters fail-safe mode.

Fail mode
Fail Detection Condition
Pulse direction error
With the door glass going up or down, the pulse that indicates door glass operation in the opposite direction is detected for 4 seconds.
Pulse stop error
With the door glass going up or down, no pulse is detected for 3.5 to 4.5 seconds.

  1. The power window control system prohibits the following power window operation when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.

    Power window control system 
    Power window operation
    Ignition switch on (IG)
    Key-off
    (Within approx. 45 seconds after ignition switch turned off)
    Key-off
    (After approx. 45 seconds elapsed after ignition switch turned off)
    Manual UP
    Operation prohibited
    Operation prohibited
    Operation prohibited
    Manual DOWN
    Operative
    (Jam protection not operative)
    Operation prohibited
    Operation prohibited
    AUTO UP
    (hold switch at AUTO UP position)
    Operative
    (in MANUAL mode)
    (Jam protection not operative)
    Operation prohibited
    Operation prohibited
    AUTO UP
    Operation prohibited
    Operation prohibited
    Operation prohibited
    AUTO DOWN
    Operation prohibited
    Operation prohibited
    Operation prohibited

    HINT:
    When the pulse sensor is normal, the AUTO UP/DOWN function can be resumed by deactivating fail-safe mode. To deactivate fail-safe mode, pull up the driver door power window switch to the AUTO UP position and hold it for at least 1 second to fully close the window from the fully open position.

  2. If the LIN communication system malfunctions (communication blackout), the power window control system prohibits the following operations.

    LIN communication system 
    Power window operation
    Ignition switch on (IG)
    MANUAL UP
    Operative (Jam protection operative)
    MANUAL DOWN
    Operative (Jam protection not operative)
    AUTO UP (hold switch at AUTO UP position)
    Operation prohibited
    AUTO UP
    Operation prohibited
    AUTO DOWN
    Operation prohibited