REFRIGERANT > REPLACEMENT |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start the engine.
Turn the A/C switch on.
Operate the cooler compressor at an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant. This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. CHARGE WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge with refrigerant HFC-134a (R134a).

| 3. WARM UP ENGINE |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 4. INSPECT FOR REFRIGERANT LEAK |
After recharging with refrigerant gas, inspect for refrigerant leak using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a gas leak detector, inspect for refrigerant leak from the refrigerant lines.
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off, and then turn the detector on.
If a gas leak is not detected from the drain hose, remove the blower motor from the cooling unit. Insert the gas leak detector into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.