POWER WINDOW CONTROL SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect Techstream to the DLC3.
Turn the ignition switch on (IG).
Turn on Techstream.
Enter the following menus.
Select: Body / D-Door Motor / DATA LIST.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| D Door P/W Auto SW | Driver door power window auto switch signal/ON or OFF | ON: Driver door power window auto switch operates OFF: Driver door power window auto switch does not operate | - |
| D Door P/W Up SW | Driver door power window manual up switch signal/ON or OFF | ON: Driver door power window manual up switch operates OFF: Driver door power window manual up switch does not operate | - |
| D Door P/W Down SW | Driver door power window manual down switch signal/ON or OFF | ON: Driver door power window manual down switch operates OFF: Driver door power window manual down switch does not operate | - |
| Glass Position (Close - 1/4) | Jam protection operation within range of fully closed to 1/4 open window glass position/OK or CAUTION | OK: Margin is sufficient during manual UP operation CAUTION: May be displayed even when no resistance is applied in each position. In this case, there is a foreign object stuck in that position. | - |
| Glass Position (1/4 - 2/4) | Jam protection operation within range of 1/4 to 1/2 open window glass position/OK or CAUTION | OK: Margin is sufficient during manual UP operation CAUTION: May be displayed even when no resistance is applied in each position. In this case, there is a foreign object stuck in that position. | - |
| Glass Position (2/4 - 3/4) | Jam protection operation within range of 1/2 to 3/4 open window glass position/OK or CAUTION | OK: Margin is sufficient during manual UP operation CAUTION: May be displayed even when no resistance is applied in each position. In this case, there is a foreign object stuck in that position. | - |
| Glass Position (3/4 - Open) | Jam protection operation within range of 3/4 to fully open window glass position/OK or CAUTION | OK: Margin is sufficient during manual UP operation CAUTION: May be displayed even when no resistance is applied in each position. In this case, there is a foreign object stuck in that position. | - |
| Number of Trouble codes | Number of DTC recorded / min.: 0, max.: 255 | Min.: 0 Max.: 255 | - |
Select: Body / Main Body / DATA LIST.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Communication D Door Motor | Connection status between power window regulator motor assembly (driver door) and main body ECU (Instrument panel junction block)/OK/Stop | OK: Communication is normal STOP: Communication is stopped | - |
| D Door Courtesy SW | Driver side door courtesy switch signal/ON or OFF | ON: Driver side door is open OFF: Driver side door is closed | - |
| ACTIVE TEST |
Connect Techstream to the DLC3.
Turn the ignition switch on (IG).
Turn on Techstream.
Enter the following menus.
Select: Body / D-Door Motor / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Power Window | Power window | UP or OFF | - |
| Power Window | Power window | DOWN or OFF | - |
Select: Body / Main Body / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| IG OFF P/W Control Permission Output | Power window | ON or OFF (After ignition switch is turned off) | - |