AUTOMATIC LIGHT CONTROL SENSOR > INSPECTION |
| 1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Manual Air Conditioning System) |
![]() |
Disconnect the F2 automatic light control sensor connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F2-3 (CLTB) - F2-6 (CLTE) | Ignition switch off | Below 1 V |
| Ignition switch on (IG) | 10 to 14 V |
| Tester Connection | Specified Condition |
| F2-6 (CLTE) - Body ground | Below 1 Ω |
![]() |
Reconnect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
![]() |
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
| F2-6 (CLTE) - F2-4 (CLTS) | 5 V/DIV., 5 ms./DIV | Ignition switch on (IG), light control switch in AUTO | Correct waveform is as shown |
| 2. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Automatic Air Conditioning System) |
![]() |
Disconnect the F1 automatic light control sensor connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F1-6 (CLTB) - F1-3 (CLTE) | Ignition switch off | Below 1 V |
| Ignition switch on (IG) | 10 to 14 V |
| Tester Connection | Specified Condition |
| F1-3 (CLTE) - Body ground | Below 1 Ω |
![]() |
Reconnect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
![]() |
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
| F1-3 (CLTE) - F1-5 (CLTS) | 5 V/DIV., 5 ms./DIV | Ignition switch on (IG), light control switch in AUTO | Correct waveform is as shown |