Home › BODY ELECTRICAL › LIGHTING › AUTOMATIC LIGHT CONTROL SENSOR

AUTOMATIC LIGHT CONTROL SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Manual Air Conditioning System)


    B109993E40
  1. Disconnect the F2 automatic light control sensor connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F2-3 (CLTB) - F2-6 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard resistance:
    Tester Connection
    Specified Condition
    F2-6 (CLTE) - Body ground
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.



    E142674E02
  1. Reconnect the automatic light control sensor connector.

  1. Connect an oscilloscope to the automatic light control sensor connector.



    B113714E01
  1. Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Condition
    Specified Condition
    F2-6 (CLTE) - F2-4 (CLTS)
    5 V/DIV., 5 ms./DIV
    Ignition switch on (IG), light control switch in AUTO
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, replace the automatic light control sensor.



2. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Automatic Air Conditioning System)


    B109993E42
  1. Disconnect the F1 automatic light control sensor connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F1-6 (CLTB) - F1-3 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard resistance:
    Tester Connection
    Specified Condition
    F1-3 (CLTE) - Body ground
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.



    E142674E01
  1. Reconnect the automatic light control sensor connector.

  1. Connect an oscilloscope to the automatic light control sensor connector.



    B113714E01
  1. Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Condition
    Specified Condition
    F1-3 (CLTE) - F1-5 (CLTS)
    5 V/DIV., 5 ms./DIV
    Ignition switch on (IG), light control switch in AUTO
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, replace the automatic light control sensor.