AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > TERMINALS OF ECU |
| CHECK AIR CONDITIONING AMPLIFIER |

Measure the voltage of the connectors.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| D37-1 (IG+) - D37-14 (GND) | GR - W-B | Power source (IG) | Ignition switch on (IG) | 11 to 14 V |
| D37-2 (SOL+) - D37-14 (GND) | L - W-B | Air conditioning compressor operation signal | Engine idling | Pulse generation (see waveform 1) |
| Blower switch LO | ||||
| Air Conditioning switch ON | ||||
| D37-3 (PTC1) - Body ground (*1) | P - Body ground | PTC NO. 1 heater relay operation signal | Engine idling | Below 1 V → 11 to 14 V |
| Set temperature: MAX HOT | ||||
| Engine coolant temperature: Below 65°C (149°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch OFF → LO | ||||
| D37-4 (PTC3) - Body ground (*1) | W - Body ground | PTC NO. 3 heater relay operation signal | Engine idling | Below 1 V → 11 to 14 V |
| Set temperature: MAX HOT | ||||
| Engine coolant temperature: Below 65°C (149°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch OFF → LO | ||||
| D37-5 (TAM) - D37-14 (GND) | B - W-B | Ambient temperature sensor signal | Ignition switch on (IG) | 1.8 to 2.2 V |
| Ambient temperature: 25°C (77°F) | ||||
| D37-8 (LOCK) - D37-14 (GND) | V - W-B | Air compressor lock sensor signal | Engine idling | Pulse generation (see waveform 5) |
| Air Conditioning switch ON | ||||
| Blower switch LO | ||||
| D37-9 (PRE) - D37-13 (SG-2) | R - SB | Air conditioning pressure sensor signal | Refrigerant pressure: Normal | 0.76 to 4.74 V |
| D37-9 (PRE) - D37-13 (SG-2) | R - SB | Air conditioning pressure sensor signal | Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2, 28 psi]) | 0.5 to 4.83 V |
| D37-9 (PRE) - D37-13 (SG-2) | R - SB | Air conditioning pressure sensor signal | Refrigerant pressure: Abnormal (more than 3.03 MPa [32 kgf/cm2, 455 psi]) | 4.74 V or higher |
| D37-10 (S5-3) - D37-14 (GND) | O - W-B | Power supply for pressure sensor | Ignition switch on (IG) | 4.5 to 5.5 V |
| D37-11 (CANH) - D37-14 (GND) | LG - W-B | Hi-level CAN bus line | Ignition switch on (IG) | Pulse generation (see waveform 3) |
| D37-12 (CANL) - D37-14 (GND) | W - W-B | Lo-level CAN bus line | Ignition switch on (IG) | Pulse generation (see waveform 4) |
| D37-13 (SG-2) - Body ground | SB - Body ground | Ground for pressure sensor | Always | Below 1 V |
| D37-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| D37-20 (MGC) - D37-14 (GND) | V - W-B | Air conditioning compressor magnetic clutch operation signal | Engine idling | Below 1 V |
| Blower switch LO | ||||
| Air Conditioning switch ON | ||||
| D37-21 (B) - D37-14 (GND) | LG - W-B | Power source (Back-up) | Always | 11 to 14 V |
| D37-22 (PTC2) - Body ground (*1) | G - Body ground | PTC NO. 2 heater relay operation signal | Engine idling | Below 1 V → 11 to 14 V |
| Set temperature: MAX HOT | ||||
| Engine coolant temperature: Below 65°C (149°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch OFF → LO | ||||
| D37-23 (BLW) - D37-14 (GND) | R - W-B | Blower motor control signal | Ignition switch on (IG) | Pulse generation (see waveform 2) |
| Blower switch LO | ||||
| D37-25 (ALT) - Body ground (*1) | SB - Body ground | Generator signal | Engine idling | Pulse generation |
| D37-29 (TR) - D37-35 (SG-4) | BR- LG | Room temperature sensor signal (for Front) | Ignition switch on (IG) | 1.8 to 2.2 V |
| Vehicle interior temperature: 25°C (77°F) | ||||
| D37-32 (TSP) - D37-14 (GND) | Y - W-B | Front passenger side solar sensor signal | Ignition switch on (IG) | 0.8 to 4.3 V |
| Solar sensor subject to electric light | ||||
| D37-33 (TSD) - D37-14 (GND) | O - W-B | Driver side solar sensor signal | Ignition switch on (IG) | 0.8 to 4.3 V |
| Solar sensor subject to electric light | ||||
| D37-35 (SG-4) - Body ground | LG - Body ground | Ground for room temperature sensor (for Front) | Always | Below 1 V |
| D37-37 (LIN1) - D37-14 (GND) | R - W-B | LIN communication signal | Ignition switch on (IG) | Pulse generation |
| D37-38 (RDEF) - D37-14 (GND) | W - W-B | Rear defogger switch signal | Ignition switch on (IG) Rear defogger switch OFF | 11 to 14 V |
| D37-38 (RDEF) - D37-14 (GND) | W - W-B | Rear defogger switch signal | Ignition switch on (IG) Rear defogger switch ON | Below 1 V |
| D38-1 (RBUS) - D38-21 (RBUG) (*2) | R - V | BUS IC control signal (for Rear) | Ignition switch on (IG) | Pulse generation |
| D38-4 (TEC) - D38-19 (SGND) (*2) | B - GR | Evaporator temperature sensor signal (for Rear) | Ignition switch on (IG) | 1.4 to 1.8 V |
| Evaporator temperature: 15°C (59°F) | ||||
| D38-7 (SG-6) - Body ground (*3) | W - Body ground | Ground for room temperature sensor signal (for Rear) | Always | Below 1 V |
| D38-13 (RLIN) - D38-20 (GND2) (*2) | B - SB | LIN communication signal (for Rear) | Ignition switch on (IG) | Pulse generation |
| D38-17 (TR) - D38-7 (SG-6) (*3) | BR - W | Room temperature sensor signal (for Rear) | Ignition switch on (IG) | 1.8 to 2.2 V |
| Vehicle interior temperature: 25°C (77°F) | ||||
| D38-19 (SGND) - Body ground (*2) | GR - Body ground | Ground for evaporator temperature sensor signal (for Rear) | Always | Below 1 V |
| D38-20 (GND2) - Body ground (*2) | SB - Body ground | Ground for power supply | Always | Below 1 V |
| D38-21 (RBUG) - Body ground (*2) | V - Body ground | Ground for BUS IC (for Rear) | Always | Below 1 V |
| D38-22 (BLWH) - D38-20 (GND2) (*2) | G - SB | Blower motor control signal (for Rear) | Ignition switch on (IG) | Pulse generation |
| Blower switch LO | ||||
| D38-23 (RBBU) - D38-21 (RBUG) (*2) | Y - V | Power supply for BUS IC (for Rear) | Ignition switch on (IG) | 11 to 14 V |
| D38-24 (+B2) - D38-20 (GND2) (*2) | LG - SB | Power source (Back-up) (for Rear) | Always | 11 to 14 V |
| z17-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z17-3 (BUS) - z17-2 (BUS G) | - | BUS IC control signal | Ignition switch on (IG) | Pulse generation |
| z17-4 (B BUS) - z17-2 (BUS G) | - | Power supply for BUS IC | Ignition switch on (IG) | 11 to 14 V |
| z17-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 V |
| z17-6 (TEA) - z17-5 (SGA) | - | Evaporator temperature sensor signal (for Front) | Ignition switch on (IG) | 1.4 to 1.8 V |
| Evaporator temperature: 15°C (59°F) |
![]() |
Using an oscilloscope, check waveform 1.
| Item | Content |
| Tester Connection | D37-2 (SOL+) - D37-14 (GND) |
| Tool Setting | 5 V/DIV., 500 μsec./DIV. |
| Condition | Engine idling, Blower switch LO, air conditioning switch ON |
![]() |
Using an oscilloscope, check waveform 2.
| Item | Content |
| Tester Connection | D37-23 (BLW) - D37-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch on (IG), Blower switch LO |
![]() |
Using an oscilloscope, check waveform 3.
| Item | Content |
| Tester Connection | D37-11 (CANH) - D37-14 (GND) |
| Tool Setting | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch on (IG) |
![]() |
Using an oscilloscope, check waveform 4.
| Item | Content |
| Tester Connection | D37-12 (CANL) - D37-14 (GND) |
| Tool Setting | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch on (IG) |
![]() |
Using an oscilloscope, check waveform 5.
| Item | Content |
| Tester Connection | D37-8 (LOCK) - D37-14 (GND) |
| Tool Setting | 200 mV/DIV., 10 ms./DIV. |
| Condition | Engine is running Blower switch: LO Air conditioning switch: ON |
| CHECK FRONT AIR CONDITIONING CONTROL |

Measure the voltage of the connectors.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| E10-2 (IG+) - E10-10 (GND) | V - GR | Power source (IG) | Ignition switch on (IG) | 11 to 14 V |
| E10-5 (LIN1) - E10-10 (GND) | R - GR | LIN communication signal | Ignition switch on (IG) | Pulse generation |
| E10-10 (GND) - Body ground | GR - Body ground | Ground for front air conditioning control | Always | Below 1 V |
| CHECK REAR AIR CONDITIONING CONTROL (for Rear Air Conditioning) |

Measure the voltage of the connectors.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| R1-2 (IG+) - R1-10 (E) | V - W-B | Power source (IG) | Ignition switch on (IG) | 11 to 14 V |
| R1-5 (MPX-) - R1-10 (E) | B - W-B | LIN communication signal | Ignition switch on (IG) | Pulse generation |
| R1-10 (E) - Body ground | W-B - Body ground | Ground for rear air conditioning control | Always | Below 1 V |