Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > TERMINALS OF ECU

for Preparation Click here



CHECK AIR CONDITIONING AMPLIFIER

E127561E03

  1. Measure the voltage of the connectors.

    HINT:
    Check from the rear of the connector while it is connected to the air conditioning amplifier.


    Tester Connection
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    D37-1 (IG+) - D37-14 (GND)
    GR - W-B
    Power source (IG)
    Ignition switch on (IG)
    11 to 14 V
    D37-2 (SOL+) - D37-14 (GND)
    L - W-B
    A/C compressor operation signal
    Engine idling
    Pulse generation
    (see waveform 1)
    Blower switch LO
    A/C switch ON
    D37-3 (PTC1) - Body ground (*1)
    P - Body ground
    PTC NO. 1 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D37-4 (PTC3) - Body ground (*1)
    W - Body ground
    PTC NO. 3 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D37-5 (TAM) - D37-14 (GND)
    B - W-B
    Ambient temperature sensor signal
    Ignition switch on (IG)
    1.8 to 2.2 V
    Ambient temperature: 25°C (77°F)
    D37-8 (LOCK) - D37-14 (GND)
    V - W-B
    Air compressor lock sensor signal
    Engine idling
    Pulse generation
    (see waveform 5)
    A/C switch ON
    Blower switch LO
    D37-9 (PRE) - D37-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Normal
    0.76 to 4.74 V
    D37-9 (PRE) - D37-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2, 28 psi])
    0.5 to 4.83 V
    D37-9 (PRE) - D37-13 (SG-2)
    R - SB
    Air conditioning pressure sensor signal
    Refrigerant pressure: Abnormal (more than 3.14 MPa [32 kgf/cm2, 455 psi])
    4.74 V or higher
    D37-10 (S5-3) - D37-14 (GND)
    O - W-B
    Power supply for pressure sensor
    Ignition switch on (IG)
    4.5 to 5.5 V
    D37-11 (CANH) - D37-14 (GND)
    LG - W-B
    Hi-level CAN bus line
    Ignition switch on (IG)
    Pulse generation
    (see waveform 3)
    D37-12 (CANL) - D37-14 (GND)
    W - W-B
    Lo-level CAN bus line
    Ignition switch on (IG)
    Pulse generation
    (see waveform 4)
    D37-13 (SG-2) - Body ground
    SB - Body ground
    Ground for pressure sensor
    Always
    Below 1 V
    D37-14 (GND) - Body ground
    W-B - Body ground
    Ground for main power supply
    Always
    Below 1 V
    D37-20 (MGC) - D37-14 (GND)
    V - W-B
    A/C compressor magnetic clutch operation signal
    Engine idling
    Below 1 V
    Blower switch LO
    A/C switch ON
    D37-21 (B) - D37-14 (GND)
    LG - W-B
    Power source (Back-up)
    Always
    11 to 14 V
    D37-22 (PTC2) - Body ground (*1)
    G - Body ground
    PTC NO. 2 heater relay operation signal
    Engine idling
    Below 1 V → 11 to 14 V
    Set temperature: MAX HOT
    Engine coolant temperature: Below 65°C (149°F)
    Ambient temperature: Below 10°C (50°F)
    Blower switch OFF → LO
    D37-23 (BLW) - D37-14 (GND)
    R - W-B
    Blower motor control signal
    Ignition switch on (IG)
    Pulse generation
    (see waveform 2)
    Blower switch LO
    D37-25 (ALT) - Body ground (*1)
    SB - Body ground
    Generator signal
    Engine idling
    Pulse generation
    D37-37 (LIN1) - D37-14 (GND)
    R - W-B
    LIN communication signal
    Ignition switch on (IG)
    Pulse generation
    D37-38 (RDEF) - D37-14 (GND)
    W - W-B
    Rear defogger switch signal
    Ignition switch on (IG)
    Rear defogger switch OFF
    11 to 14 V
    D37-38 (RDEF) - D37-14 (GND)
    W - W-B
    Rear defogger switch signal
    Ignition switch on (IG)
    Rear defogger switch ON
    Below 1 V
    z17-2 (BUS G) - Body ground
    -
    Ground for BUS IC
    Always
    Below 1 V
    z17-3 (BUS) - z17-2 (BUS G)
    -
    BUS IC control signal
    Ignition switch on (IG)
    Pulse generation
    z17-4 (B BUS) - z17-2 (BUS G)
    -
    Power supply for BUS IC
    Ignition switch on (IG)
    11 to 14 V
    z17-5 (SGA) - Body ground
    -
    Ground for evaporator temperature sensor
    Always
    Below 1 V
    z17-6 (TEA) - z17-5 (SGA)
    -
    Evaporator temperature sensor signal
    Ignition switch on (IG)
    1.4 to 1.8 V
    Evaporator temperature: 15°C (59°F)



  2. E074977E11
  3. Using an oscilloscope, check waveform 1.
    Compressor and pulley operation signal 
    Item
    Content
    Tester Connection
    D37-2 (SOL+) - D37-14 (GND)
    Tool Setting
    5 V/DIV., 500 μsec./DIV.
    Condition
    Engine idling, Blower switch LO, A/C switch ON



  4. E103396E05
  5. Using an oscilloscope, check waveform 2.
    Blower motor control signal 
    Item
    Content
    Tester Connection
    D37-23 (BLW) - D37-14 (GND)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Ignition switch on (IG), Blower switch LO

    HINT:
    When the blower level is increased, the duty ratio changes accordingly.



  6. A086154E10
  7. Using an oscilloscope, check waveform 3.
    CAN communication signal 
    Item
    Content
    Tester Connection
    D37-11 (CANH) - D37-14 (GND)
    Tool Setting
    1 V/DIV., 10 μsec./DIV.
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.



  8. A086155E11
  9. Using an oscilloscope, check waveform 4.
    CAN communication signal 
    Item
    Content
    Tester Connection
    D37-12 (CANL) - D37-14 (GND)
    Tool Setting
    1 V/DIV., 10 μsec./DIV.
    Condition
    Ignition switch on (IG)

    HINT:
    The waveform varies depending on the CAN communication signal.



  10. E147961E01
  11. Using an oscilloscope, check waveform 5.
    A/C compressor lock sensor signal 
    Item
    Content
    Tester Connection
    D37-8 (LOCK) - D37-14 (GND)
    Tool Setting
    200 mV/DIV., 10 ms./DIV.
    Condition
    Engine is running
    Blower switch: LO
    A/C switch: ON

    HINT:
    The waveform varies depending on the CAN communication signal.
    *1: w/ PTC Heater


CHECK FRONT AIR CONDITIONING CONTROL

E152670E01

  1. Measure the voltage of the connectors.

    Tester Connection
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    E10-2 (IG+) - E10-10 (GND)
    V - GR
    Power source (IG)
    Ignition switch on (IG)
    11 to 14 V
    E10-5 (LIN1) - E10-10 (GND)
    R - GR
    LIN communication signal
    LIN switch on (IG)
    Pulse generation
    E10-10 (GND) - Body ground
    GR - Body ground
    Ground for front air conditioning control
    Always
    Below 1 V