DTC B1413/13 Evaporator Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1413/13 | Open or short in evaporator temperature sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM |
Connect Techstream to the DLC3.
Turn the ignition switch on (IG) and turn Techstream main switch on.
Select the item below in the Data List, and read the value displayed on Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporator Fin Temperature | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.6°C (139.28°F) | Actual evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.6°C (139.28°F) |
| Result | Proceed to |
| NG | A |
| OK (Checking from PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
Remove the No. 1 cooler thermistor.

Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| 1 - 2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| 1 - 2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| 1 - 2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| 1 - 2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| 1 - 2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| 1 - 2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| 1 - 2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| 1 - 2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
|
| ||||
| OK | |
| 3.INSPECT AIR CONDITIONING HARNESS |
Remove the air conditioning harness.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z17-6 (TEA) - 2 | Always | Below 1 Ω |
| z17-5 (SGA) - 1 | Always | Below 1 Ω |
| z17-6 (TEA) - Body Ground | Always | 10 kΩ or higher |
| z17-5 (SGA) - Body Ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||