AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > SYSTEM DESCRIPTION |
| GENERAL |
The air conditioning system has the following features:
| MODE POSITION AND DAMPER OPERATION |

| Control Damper | Control Position | Damper Position | Operation | ||
| Air Inlet Control Damper | FRESH | A | Brings in fresh air | ||
| RECIRC | B | Recirculates internal air | |||
| Air Mix Control Damper (Left/Right Independent Control) | Driver and Front Passenger Side | MAX COOL to MAX HOT (TEMP. SETTING 18 to 32°C (65 to 85°F)) | C, D, E | Varies mixture ratio of fresh air and recirculation air in order to regulate temperature continuously from HOT to COOL | |
| Mode Control Film Damper | Driver and Front Passenger Side | ![]() FACE | I, J, L, O, U | Air blows out of center registers and side registers. | |
![]() BI-LEVEL | I, M, Q, R, T | Air mainly blows out of center registers, side registers, and footwell register ducts. | |||
![]() FOOT | H, K, N, P, S | Air mainly blows out of front and rear footwell register ducts. In addition, air blows out slightly from front and side defrosters, and side registers. | |||
![]() FOOT/DEF | G, K, N, P, S | Air mainly blows out of front and side defrosters to defrost windshield. Air also blows out from front and rear footwell register ducts, and side registers. | |||
![]() DEF | F, K, N, U, V | Air blows out of front and side defrosters and side registers to defrost windshield. | |||

| Control Damper | Control Position | Damper Position | Operation |
| Air Mix Control Damper | MAX COOL to MAX HOT TEMP. SETTING 18 to 32°C (65 to 90°F) | D, E | Varies mixture ratio of fresh air and recirculating air in order to regulate temperature continuously from HOT to COOL |
| Mode Control Film Damper | ![]() FACE | A | Air blows out of roof face ducts. |
![]() BI-LEVEL | B | Air blows out of roof face ducts and rear foot ducts. | |
![]() FOOT | C | Air blows out of rear foot ducts. |
| AIR OUTLET AND AIRFLOW VOLUME |

| Air Outlet Mode | Air Outlet Position Symbol | |||||
| A | B | C | D | E | ||
| Center Face | Side Face | Foot | Footwell | Defroster | ||
![]() | FACE | ![]() | ![]() | X | X | X |
![]() | BI-LEVEL | ![]() | ![]() | ![]() | ![]() | X |
![]() | FOOT | X | ![]() | ![]() | ![]() | ![]() |
![]() | FOOT/DEF | X | ![]() | ![]() | ![]() | ![]() |
![]() | DEF | X | ![]() | X | X | ![]() |

| Air Outlet Mode | Air Outlet Position Symbol | ||
| A | B | ||
| Side Face | Rear Foot | ||
![]() | FACE | ![]() | X |
![]() | BI-LEVEL | ![]() | ![]() |
![]() | FOOT | X | ![]() |