AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
Connect Techstream to the DLC3.
Turn the ignition switch on (IG) and turn Techstream on.
Read the Data List by following the prompts on the tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual cabin temperature is displayed | Open in circuit: -6.5°C (20.3°F) Short in circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Solar Sensor (D side) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor value increases as brightness increases | Open in circuit: 0 Short in circuit: 255 |
| Solar Sensor (P Side) | Passenger side solar sensor / Min.: 0, Max.: 255 | Front passenger side solar sensor value increases as brightness increases | Open in circuit: 0 Short in circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed | - |
| Set Temperature (D Side) | Driver side set temperature / Min.: 0°C (32°F) Max.: 30°C (86°F) | Driver side actual set temperature is displayed | - |
| Set Temperature (P Side) | Passenger side set temperature / Min.: 0°C (32°F) Max.: 30°C (86°F) | Front passenger side actual set temperature is displayed | - |
| Blower motor speed Level | Blower motor speed level / Min.: 0, Max.: 31 | Increases in range between 0 and 31 as blower motor speed increases | - |
| Adjusted Ambient Temp | Adjusted ambient Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | Adjusted ambient temperature is displayed | - |
| Air Mix Sensor Targ Pulse(D) | Driver side air mix control servo motor target pulse / Min.: 0, Max.: 255 | MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) | - |
| Air Mix Sensor Targ Pulse(P) | Passenger side air mix control servo motor target pulse / Min.: 0, Max.: 255 | MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) | - |
| Air Outlet Servo Pulse(D) | Driver side air outlet control servo motor target / Min.: 0, Max.: 255 | FACE: 8 (pulse) B/L: 30 (pulse) FOOT: 67 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse / Min.: 0, Max.: 255 | RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) | - |
| Evaporator Fin Temperature | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: 0 kgf/cm2G Max.: 38.25 kgf/cm2G | Actual regulator pressure is displayed | - |
| Regulator Control Current | Regulator control current / Min.: 0 A Max.: 0.997 A | Value changes between 0 A and 0.997 A in accordance with compressor operation | - |
| Room Temp Sensor(Rear) | Rear room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual rear cabin temperature is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor(Rear) | Rear evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual rear evaporator temperature is displayed | - |
| Set Temperature (Rear) | Rear side set temperature / Min.: 0 Max.: 255 | Rear side actual rear set temperature is displayed | - |
| Blower Motor Level(Rear) | Rear blower motor speed level / Min.; 0, Max.: 31 | Increases in range between 0 and 31 as rear blower motor speed increases | - |
| Air Outlet Servo Pulse(R) | Rear side air outlet control servo motor target pulse / Min.: 0, Max.: 255 | Rr FACE: 83 (pulse) Rr B/L: 38 (pulse) Rr FOOT: 7 (pulse) | - |
| Air Mix Servo Targ Pulse(R) | Rear side air mix control servo motor target pulse / Min.: 0, Max.: 255 | MAX. COLD: 9 (pulse) MAX. HOT: 54 (pulse) | - |
| #Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs displayed | - |
| PERFORM ACTIVE TEST |
Connect Techstream to the DLC3.
Turn the ignition switch on (IG) and turn Techstream on.
Perform the Active Test by following the prompts on the tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | Magnetic clutch relay | OFF, ON | - |
| Defogger Relay(Rear) | Defogger relay (Rear) | OFF, ON | - |
| Electric Heater1 | PTC heater 1 | OFF, ON | - |
| Electric Heater2 | PTC heater 2 | OFF, ON | - |
| Electric Heater3 | PTC heater 3 | OFF, ON | - |
| Air Mix Servo Targ Pulse(D) | Air mix servo motor pulse (D side) | Min.: 5, Max.: 103 | - |
| Air Mix Servo Targ Pulse(P) | Air mix servo motor pulse (P side) | Min.: 7, Max.: 105 | - |
| Air Outlet Servo Targ Pulse(D) | Air outlet servo motor pulse (D side) | Min.: 8, Max.: 97 | - |
| Air Inlet Damper Targ Pulse(D) | Air inlet damper target pulse | Min.: 7, Max.: 28 | - |
| Rear Blower Motor | Rear blower motor | Min.: 0, Max.: 31 | - |
| Rear Air Mix Servo Targ Pulse | Rear air mix control servo motor pulse | Min.: 9, Max.: 54 | - |