AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Steering Pad Switch Circuit |

| 1.INSPECT AIR CONDITIONING CONTROL ASSEMBLY |
![]() |
Remove the air conditioning control assembly (Click here) with the connectors still connected.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E10-4 (ADI1) - E10-9 (SG) | AUTO switch: ON | Below 2.5 Ω |
| E10-4 (ADI1) - E10-9 (SG) | OFF switch: ON | Approx. 329 Ω |
| E10-4 (ADI1) - E10-9 (SG) | TEMP+ switch: ON | Approx. 1000 Ω |
| E10-4 (ADI1) - E10-9 (SG) | TEMP- switch: ON | Approx. 3110 Ω |
|
| ||||
| OK | ||
| ||
| 2.INSPECT STEERING PAD SWITCH ASSEMBLY |
Remove the steering pad switch assembly.
Disconnect the connector from the steering pad switch assembly.

Measure the resistance according to the value(s) in the table below.
| Tester Connection (Symbols) | Condition | Specified Condition |
| z2-3 (AC1) - z2-2 (EAC) | AUTO switch: ON | Below 2.5 Ω |
| z2-3 (AC1) - z2-2 (EAC) | OFF switch: ON | Approx. 329 Ω |
| z2-3 (AC1) - z2-2 (EAC) | TEMP+ switch: ON | Approx. 1000 Ω |
| z2-3 (AC1) - z2-2 (EAC) | TEMP- switch: ON | Approx. 3110 Ω |
|
| ||||
| OK | |
| 3.INSPECT SPIRAL CABLE SUB-ASSEMBLY |
![]() |
Disconnect the connector from the spiral cable sub-assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D16-10 (AC1) - z2-3 (AC1) | Center | Below 1 Ω |
| D16-10 (AC1) - z2-3 (AC1) | 2.5 rotations to the left | Below 1 Ω |
| D16-10 (AC1) - z2-3 (AC1) | 2.5 rotations to the right | Below 1 Ω |
| D16-9 (EAC) - z2-2 (EAC) | Center | Below 1 Ω |
| D16-9 (EAC) - z2-2 (EAC) | 2.5 rotations to the left | Below 1 Ω |
| D16-9 (EAC) - z2-2 (EAC) | 2.5 rotations to the right | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (A/C CONTROL ASSEMBLY - SPIRAL CABLE SUB-ASSEMBLY) |
![]() |
Disconnect the connector from the air conditioning control assembly.
Disconnect the connector from the spiral cable sub-assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E10-4 (ADI1) - D16-10 (AC1) | Always | Below 1 Ω |
| E10-9 (SG) - D16-9 (EAC) | Always | Below 1 Ω |
| E10-4 (ADI1) - D16-10 (AC1) | Always | 10 kΩ or higher |
| E10-9 (SG) - D16-9 (EAC) | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||