TURN SIGNAL FLASHER ASSEMBLY > INSPECTION |
| 1. INSPECT TURN SIGNAL FLASHER ASSEMBLY |
![]() |
Disconnect the D12 turn signal flasher assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D12-1 (IG) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch on (IG) | 11 to 14 V | |
| D12-4 (B) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D12-5 (EL) - Body ground | Turn signal switch OFF | 11 kΩ or higher |
| Turn signal switch in LH position | Below 1 Ω | |
| D12-6 (ER) - Body ground | Turn signal switch OFF | 11 kΩ or higher |
| Turn signal switch in RH position | Below 1 Ω | |
| D12-7 (E) - Body ground | Always | Below 1 Ω |
| D12-8 (HAZ) - Body ground | Hazard warning switch OFF | 11 kΩ or higher |
| Hazard warning switch ON | Below 1 Ω |
![]() |
Reconnect the D12 turn signal flasher assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D12-2 (LR) - Body ground | Hazard warning switch OFF | Below 1 V |
| Hazard warning switch ON | 11 to 14 V (60 to 120 times per minute) | |
| Turn signal switch OFF | Below 1 V | |
| Ignition switch on (IG) and turn signal switch in RH position | 11 to 14 V (60 to 120 times per minute) | |
| D12-3 (LL) - Body ground | Hazard warning switch OFF | Below 1 V |
| Hazard warning switch ON | 11 to 14 V (60 to 120 times per minute) | |
| Turn signal switch OFF | Below 1 V | |
| Ignition switch on (IG) and turn signal switch in LH position | 11 to 14 V (60 to 120 times per minute) |