DTC P0327 Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor) |
DTC P0328 Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor) |
DTC P0332 Knock Sensor 2 Circuit Low Input (Bank 2) |
DTC P0333 Knock Sensor 2 Circuit High Input (Bank 2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0327 P0332 | Output voltage of knock sensor 1 or 2 is less than 0.5 V (1 trip detection logic) |
|
| P0328 P0333 | Output voltage of knock sensor 1 or 2 is more than 4.5 V (1 trip detection logic) |
|

| Item | Content |
| Terminals | KNK1 - EKNK or KNK2 - EKN2 |
| Equipment Settings | 0.01 to 10 V/DIV., 0.01 to 10 ms./DIV. |
| Conditions | Keep engine speed at 4000 rpm with warm engine |
| Related DTCs | P0327: Knock sensor (Bank 1) open/short (Low voltage) P0328: Knock sensor (Bank 1) open/short (High voltage) P0332: Knock sensor (Bank 2) open/short (Low voltage) P0333: Knock sensor (Bank 2) open/short (High voltage) |
| Required Sensors / Components (Main) | Knock sensor (Bank 1 and 2) |
| Required Sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Battery voltage | 10.5 V or more |
| Time after engine start | 5 seconds or more |
| Ignition switch | ON (IG) |
| Starter | OFF |
| Knock sensor voltage | Less than 0.5 V |
| Knock sensor voltage | More than 4.5 V |

| 1.READ VALUE USING DTC OUTPUT (CHECK KNOCK SENSOR CIRCUIT) |
![]() |
Disconnect the Bd1 connector.
Using lead wires, connect the connectors as follows.
| Male Connector - Female Connector |
| Terminal 2 - Terminal 4 |
| Terminal 1 - Terminal 3 |
| Terminal 4 - Terminal 2 |
| Terminal 3 - Terminal 1 |
Warm up the engine.
Run the engine at 3000 rpm for 10 seconds or more.
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG) and turn the Techstream on.
Select the following menu items: Powertrain / Engine and ECT / Trouble Code.
Read the DTCs.
| Display | Proceed to |
| DTCs that are same as when vehicle brought in P0327, P0328 → P0327, P0328 or P0332, P0333 → P0332, P0333 | A |
| DTCs that are different from when vehicle brought in P0327, P0328 → P0332, P0333 or P0332, P0333 → P0327, P0328 | B |
Reconnect the Bd1 connector.
|
| ||||
| A | |
| 2.CHECK HARNESS OR CONNECTOR (Ba1 CONNECTOR - ECM) |
![]() |
Disconnect the Bd1 connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 female connector 2 - B2-29 (KNK1) | Always | Below 1 Ω |
| Bd1 female connector 1 - B2-28 (EKNK) | Always | Below 1 Ω |
| Bd1 female connector 4 - B2-21 (KNK2) | Always | Below 1 Ω |
| Bd1 female connector 3 - B2-20 (EKN2) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| Bd1 female connector 2 or B2-29 (KNK1) - Body ground | Always | 10 kΩ or higher |
| Bd1 female connector 1 or B2-28 (EKNK) - Body ground | Always | 10 kΩ or higher |
| Bd1 female connector 4 or B2-21 (KNK2) - Body ground | Always | 10 kΩ or higher |
| Bd1 female connector 3 or B2-20 (EKN2) - Body ground | Always | 10 kΩ or higher |
Reconnect the Bd1 connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 3.INSPECT ECM |
![]() |
Disconnect the ECM connector.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B2-29 (KNK1) - B2-28 (EKNK) | Ignition switch on (IG) | 4.5 to 5.5 V |
| B2-21 (KNK2) - B2-20 (EKN2) | Ignition switch on (IG) | 4.5 to 5.5 V |
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 4.INSPECT KNOCK SENSOR |
![]() |
Disconnect the Bd1 connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 1 - 2 | Always | 120 to 280 kΩ |
| Bd1 male connector 3 - 4 | Always | 120 to 280 kΩ |
Reconnect the Bd1 connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (Ba1 CONNECTOR - KNOCK SENSOR) |
![]() |
Disconnect the Bd1 connector.
Disconnect the knock sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 2 - d2-2 | Always | Below 1 Ω |
| Bd1 male connector 1 - d2-1 | Always | Below 1 Ω |
| Bd1 male connector 4 - d1-2 | Always | Below 1 Ω |
| Bd1 male connector 3 - d1-1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 2 or d2-2 - Body ground | Always | 10 kΩ or higher |
| Bd1 male connector 1 or d2-1 - Body ground | Always | 10 kΩ or higher |
| Bd1 male connector 4 or d1-2 - Body ground | Always | 10 kΩ or higher |
| Bd1 male connector 3 or d1-1 - Body ground | Always | 10 kΩ or higher |
Reconnect the Bd1 connector.
Reconnect the knock sensor connectors.
|
| ||||
| OK | ||
| ||