DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | Open or short in mass air flow meter circuit for 3 seconds |
|
| P0102 | Open in mass air flow circuit for 3 seconds |
|
| P0103 | Short in mass air flow circuit for 3 seconds |
|
| Mass Air Flow Rate (gm/s) | Malfunctions |
| Approximately 0.0 |
|
| 271.0 or more | Open in E2G circuit |
| Related DTCs | P0100: Mass air flow meter range check (Fluctuating) P0102: Mass air flow meter range check (Low voltage) P0103: Mass air flow meter range check (High voltage) |
| Required Sensors / Components (Main) | Mass air flow meter |
| Required Sensors / Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate: Engine RPM less than 4000 rpm 2 driving cycles: Engine RPM 4000 rpm or more |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Mass air flow meter voltage | Less than 0.2 V, or more than 4.9 V |
| Mass air flow meter voltage | Less than 0.2 V |
| Mass air flow meter voltage | More than 4.9 V |
| Mass air flow meter voltage | Between 0.2 V and 4.9 V |

| 1.READ VALUE USING TECHSTREAM (MASS AIR FLOW RATE) |
Connect the Techstream to the DLC3.
Start the engine.
Turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / MAF.
Read the values displayed on the tester.
| Mass Air Flow Rate (gm/s) | Proceed to |
| 0.0 | A |
| 271.0 or more | B |
| Between 1.0 and 270.0 (*1) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the mass air flow meter connector.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B10-3 (+B) - Body ground | Ignition switch on (IG) | 9 to 14 V |
Reconnect the mass air flow meter connector.
|
| ||||
| OK | |
| 3.INSPECT ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage between the terminals of the ECM connector.
| Tester Connection | Condition | Specified Condition |
| B1-30 (VG) - B1-29 (E2G) | Engine idling | 0.5 to 3.0 V |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B10-5 (VG) - B1-30 (VG) | Always | Below 1 Ω |
| B10-4 (E2G) - B1-29 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B10-5 (VG) or B1-30 (VG) - Body ground | Always | 10 kΩ or higher |
| B10-4 (E2G) or B1-29 (E2G) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 5.INSPECT FUSE (EFI NO. 3 FUSE) |
![]() |
Remove the EFI No. 3 fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| EFI No. 3 fuse | Always | Below 1 Ω |
Reinstall the EFI No. 3 fuse.
|
| ||||
| OK | ||
| ||
| 6.INSPECT ECM (SENSOR GROUND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B1-29 (E2G) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B10-5 (VG) - B1-30 (VG) | Always | Below 1 Ω |
| B10-4 (E2G) - B1-29 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B10-5 (VG) or B1-30 (VG) - Body ground | Always | 10 kΩ or higher |
| B10-4 (E2G) or B1-29 (E2G) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||