DTC    P0110    Intake Air Temperature Circuit

DTC    P0112    Intake Air Temperature Circuit Low Input

DTC    P0113    Intake Air Temperature Circuit High Input

for Preparation Click here


DESCRIPTION

The intake air temperature sensor, mounted on the mass air flow meter, monitors the intake air temperature. The intake air temperature sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the intake air temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
The intake air temperature sensor is powered by a 5 V applied from the THA terminal of the ECM, via resistor R.
Resistor R and the intake air temperature sensor are connected in series. When the resistance value of the intake air temperature sensor changes, according to changes in the intake air temperature, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.
A056276E06

HINT:
When any of DTCs P0110, P0112 and P0113 are set, the ECM enters fail-safe mode. During fail-safe mode, the intake air temperature is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.


DTC No.
Proceed to
DTC Detection Condition
Trouble Area
P0110
Step 1
Open or short in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic)
  1. Open or short in intake air temperature sensor circuit
  2. Intake air temperature sensor (built into mass air flow meter)
  3. ECM
P0112
Step 4
Short in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic)
  1. Short in intake air temperature sensor circuit
  2. Intake air temperature sensor (built into mass air flow meter)
  3. ECM
P0113
Step 2
Open in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic)
  1. Open in intake air temperature sensor circuit
  2. Intake air temperature sensor (built into mass air flow meter)
  3. ECM

HINT:
When any of these DTCs are set, check the IAT by selecting the following menu items: Powertrain / Engine and ECT / Data List / All Data / Intake Air.


Temperature Displayed
Malfunctions
-40°C (-40°F)
Open circuit
140°C (284°F) or higher
Short circuit

MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the intake air temperature. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the intake air temperature sensor and sets a DTC.
Example:
  1. If the sensor voltage output is -40°C (-40°F) for 0.5 seconds or more, the ECM determines that there is an open in the intake air temperature sensor circuit, and sets DTC P0113. Conversely, if the voltage output is more than 140°C (284°F) for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and sets DTC P0112.
  2. If the malfunction is not repaired successfully, a DTC is set 0.5 seconds after the engine is next started.

MONITOR STRATEGY


Related DTCs
P0110: Intake air temperature sensor open/short (Fluctuating)
P0112: Intake air temperature sensor short (Low electrical voltage)
P0113: Intake air temperature sensor open (High electrical voltage)
Required Sensors / Components (Main)
Intake air temperature sensor
Required sensors / Components (Related)
-
Frequency of Operation
Continuous
Duration
0.5 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None

TYPICAL MALFUNCTION THRESHOLDS


P0110: 
Intake air temperature sensor voltage
Less than 0.18 V or more than 4.91 V

P0112: 
Intake air temperature sensor voltage
Less than 0.18 V [More than 140°C (284°F)]

P0113: 
Intake air temperature sensor voltage
More than 4.91 V [Less than -40°C (-40°F)]

COMPONENT OPERATING RANGE


Intake air temperature sensor voltage
0.18 V to 4.91 V [-40 to 140°C (-40 to 284°F)]

WIRING DIAGRAM


A136106E06


INSPECTION PROCEDURE

HINT:
  1. If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
  2. Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    Same as actual intake air temperature.


    Result:

    Temperature Displayed
    Proceed to
    -40°C (-40°F)
    A
    140°C (284°F) or higher
    B
    Same as actual intake air temperature
    C

    HINT:
    1. If there is an open circuit, the Techstream indicates -40°C (-40°F).
    2. If there is a short circuit, the Techstream indicates 140°C (284°F) or higher.



B
Go to step 4

C
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


2.READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS)


    A140711E07
  1. Disconnect the mass air flow meter connector.

  1. Connect terminals THA and E2 of the mass air flow meter wire harness side connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    140°C (284°F) or higher

  1. Reconnect the mass air flow meter connector.



NG
Go to step 3
OK

REPLACE MASS AIR FLOW METER (Click here)  

3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A168200E05
  1. Disconnect the mass air flow meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Condition
    Specified Condition
    B1-22 (THA) - B10-1 (THA)
    Always
    Below 1 Ω
    B1-28 (E2) - B10-2 (E2)
    Always
    Below 1 Ω
    Check for short:
    Tester Connection
    Condition
    Specified Condition
    B1-22 (THA) or B10-1 (THA) - Body ground
    Always
    10 kΩ or higher
    B1-28 (E2) or B10-2 (E2) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the mass air flow meter connector.

  1. Reconnect the ECM connector.



NG
REPLACE ECM (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (MASS AIR FLOW METER - ECM) 

4.READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS)


    A084869E87
  1. Disconnect the mass air flow meter connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    -40°C (-40°F)

  1. Reconnect the mass air flow meter connector.



NG
Go to step 5
OK

REPLACE MASS AIR FLOW METER 

5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A114609E17
  1. Disconnect the mass air flow meter connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    -40°C (-40°F)

  1. Reconnect the mass air flow meter connector.



NG
REPLACE ECM (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (MASS AIR FLOW METER - ECM)