DTC P0455 Evaporative Emission Control System Leak Detected (Gross Leak) |
DTC P0456 Evaporative Emission Control System Leak Detected (Very Small Leak) |
| DTCs | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0455 | EVAP gross leak | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at start and end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that EVAP system has a large leak. |
| While ignition switch off | 2 trip |
| P0456 | EVAP small leak | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard measured at start and end of leak check. If stabilized pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system has a small leak. | While ignition switch off | 2 trip |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch is turned off. | - |
| A | Atmospheric pressure measurement | Vent valve is turned OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak pressure measurement | In order to determine 0.02 inch leak pressure standard, leak detection pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve is turned ON (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes*2
|
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak pressure measurement | After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards. If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system is leaking. | 60 seconds |
| F | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |


| Related DTCs | P0455: Gross leak detected P0456: Very small leak (0.020 inch hole) detected |
| Required Sensors / Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Ignition switch | off |
| Time after key-off | 5 or 7 or 9.5 hours |
| Canister pressure sensor malfunction (P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions 1 and 2 are met before key-off | - |
| 1. Duration that vehicle driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| EVAP pressure when vacuum introduction is complete | Between reference pressure and reference pressure x 0.2 |
| EVAP pressure when vacuum introduction is complete | Higher than reference pressure x 0.2 |