DTC P043E Evaporative Emission System Reference Orifice Clog Up |
DTC P043F Evaporative Emission System Reference Orifice High Flow |
DTC P2401 Evaporative Emission System Leak Detection Pump Control Circuit Low |
DTC P2402 Evaporative Emission System Leak Detection Pump Control Circuit High |
DTC P2419 Evaporative Emission System Switching Valve Control Circuit Low |
| DTCs | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P043E | 0.02 inch orifice clogged | P043E, P043F, P2401, P2402, P2419 are present when one of the following conditions is met during key-off EVAP monitor
|
| While ignition switch off | 2 trip |
| P043F | 0.02 inch orifice high-flow | ||||
| P2401 | Leak detection pump stuck OFF | ||||
| P2402 | Leak detection stuck ON | ||||
| P2419 | Vent valve stuck open (vent) |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve is turned OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak pressure measurement | In order to determine 0.02 inch leak pressure standard, leak detection pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve is turned ON (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes*2
|
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak pressure measurement | After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards. If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system is leaking. | 60 seconds |
| F | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |


| Related DTCs | P043E: 0.02 inch orifice clog (built-in pump module) P043F: 0.02 inch orifice high-flow (built-in pump module) P2401: Vacuum pump stuck OFF P2402: Vacuum pump stuck ON P2419: Vent valve stuck open (vent) |
| Required Sensors / Components | Canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 2 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Ignition switch | off |
| Time after key-off | 5 or 7 or 9.5 hours |
| EVAP pressure sensor malfunction (P0451, P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions 1 and 2 are met before key-off | - |
| 1. Duration that vehicle driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| 1. One of following conditions is met | - |
| 2. EVAP pressure just after reference pressure measurement start | More than -1 kPa (-7.5 mmHg) |
| 3. Reference pressure | Less than -4.85 kPa (-36.384 mmHg) |
| 4. Reference pressure | -1.057 kPa (-7.929 mmHg) or more |
| 5. Reference pressure | Not saturated |
| 6. Difference between first reference pressure and second reference pressure | 0.7 kPa (5.25 mmHg) or more |