SHIFT LEVER > INSPECTION |
| 1. INSPECT SHIFT LOCK CONTROL ECU (w/ Smart Key System) |
![]() |
Disconnect the shift lock control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 12 (IG) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| 12 (IG) - Body ground | Ignition switch off | Below 1 V |
| 6 (STP) - Body ground | Brake pedal depressed | 10 to 14 V |
| 6 (STP) - Body ground | Brake pedal released | Below 1 V |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (E) - Body ground | Always | Below 1 Ω |
| 2. INSPECT SHIFT LOCK CONTROL ECU (w/o Smart Key System) |
![]() |
Disconnect the shift lock control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (ACC) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| 6 (ACC) - Body ground | Ignition switch on (ACC) | 10 to 14 V |
| 6 (ACC) - Body ground | Ignition switch off | Below 1 V |
| 4 (STP) - Body ground | Brake pedal depressed | 10 to 14 V |
| 4 (STP) - Body ground | Brake pedal released | Below 1 V |
| 8 (IG) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| 8 (IG) - Body ground | Ignition switch off | Below 1 V |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (E) - Body ground | Always | Below 1 Ω |
![]() |
Connect the shift lock control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 5 (KLS+) - 1 (E) | Ignition switch on (ACC) and shift lever P position | Below 1 V |
| Ignition switch on (ACC) and shift lever except P position ↓ After approx. 1 second | 7.5 to 11 V ↓ 6 to 9.5 V |
| 3. INSPECT TRANSMISSION CONTROL SWITCH |
Disconnect the transmission control switch connector from the shift lock control unit assembly.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 3 - Body ground | Ignition switch on (IG) | 10 to 14 V |
| ↑ | Ignition switch off | Below 1 V |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 5 - Body ground | Always | Below 1 Ω |
![]() |
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
| Tester Connection | Shift Position | Specified Condition |
| 3 - 7 | S, "+" and "-" | Below 1 Ω |
| ↑ | Except S, "+" and "-" | 10 kΩ or higher |
| 2 - 5 | Press continuously "+" (Up shift) | Below 1 Ω |
| ↑ | S | 10 kΩ or higher |
| 1 - 5 | Press continuously "-" (Down shift) | Below 1 Ω |
| ↑ | S | 10 kΩ or higher |
| 4. INSPECT SHIFT LOCK SOLENOID |
Disconnect the shift lock solenoid connector.
![]() |
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
| Tester Connection | Shift Position | Specified Condition |
| 1 (P) - 2 (E2) | P | 10 kΩ or higher |
| 1 (P) - 2 (E2) | Except P | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (SLS-) - 4 (SLS+) | Always | 112 Ω |