Home › TRANSMISSION · U151F AUTOMATIC TRANSAXLE › SHIFT LEVER

SHIFT LEVER > INSPECTION

for Preparation Click here



1. INSPECT SHIFT LOCK CONTROL ECU (w/ Smart Key System)


    C168466E03
  1. Disconnect the shift lock control ECU connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    12 (IG) - Body ground
    Ignition switch on (IG)
    10 to 14 V
    12 (IG) - Body ground
    Ignition switch off
    Below 1 V
    6 (STP) - Body ground
    Brake pedal depressed
    10 to 14 V
    6 (STP) - Body ground
    Brake pedal released
    Below 1 V



    C168466E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (E) - Body ground
    Always
    Below 1 Ω



2. INSPECT SHIFT LOCK CONTROL ECU (w/o Smart Key System)


    C168464E03
  1. Disconnect the shift lock control ECU connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    6 (ACC) - Body ground
    Ignition switch on (IG)
    10 to 14 V
    6 (ACC) - Body ground
    Ignition switch on (ACC)
    10 to 14 V
    6 (ACC) - Body ground
    Ignition switch off
    Below 1 V
    4 (STP) - Body ground
    Brake pedal depressed
    10 to 14 V
    4 (STP) - Body ground
    Brake pedal released
    Below 1 V
    8 (IG) - Body ground
    Ignition switch on (IG)
    10 to 14 V
    8 (IG) - Body ground
    Ignition switch off
    Below 1 V



    C168464E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (E) - Body ground
    Always
    Below 1 Ω



    C168467E01
  1. Connect the shift lock control ECU connector.

  1. Measure the voltage according to the value(s) in the table below.

    NOTICE:
    Do not disconnect the shift lock control ECU connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    5 (KLS+) - 1 (E)
    Ignition switch on (ACC) and shift lever P position
    Below 1 V
    Ignition switch on (ACC) and shift lever except P position
    ↓
    After approx. 1 second
    7.5 to 11 V
    ↓
    6 to 9.5 V



3. INSPECT TRANSMISSION CONTROL SWITCH
  1. Disconnect the transmission control switch connector from the shift lock control unit assembly.



    C110345E33
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    3 - Body ground
    Ignition switch on (IG)
    10 to 14 V
    ↑
    Ignition switch off
    Below 1 V



    C110345E33
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    5 - Body ground
    Always
    Below 1 Ω



    C110341E26
  1. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

    Standard resistance:
    Tester Connection
    Shift Position
    Specified Condition
    3 - 7
    S, "+" and "-"
    Below 1 Ω
    ↑
    Except S, "+" and "-"
    10 kΩ or higher
    2 - 5
    Press continuously
    "+"
    (Up shift)
    Below 1 Ω
    ↑
    S
    10 kΩ or higher
    1 - 5
    Press continuously
    "-"
    (Down shift)
    Below 1 Ω
    ↑
    S
    10 kΩ or higher

    If the result is not as specified, replace the shift lock control unit.



4. INSPECT SHIFT LOCK SOLENOID
  1. Disconnect the shift lock solenoid connector.



    C159129E01
  1. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

    Standard resistance:
    Tester Connection
    Shift Position
    Specified Condition
    1 (P) - 2 (E2)
    P
    10 kΩ or higher
    1 (P) - 2 (E2)
    Except P
    Below 1 Ω

    If the result is not as specified, replace the shift lock control unit.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (SLS-) - 4 (SLS+)
    Always
    112 Ω

    If the result is not as specified, replace the shift lock control unit.