Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REAR EVAPORATOR TEMPERATURE SENSOR

REAR EVAPORATOR TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT EVAPORATOR TEMPERATURE SENSOR


    E127592E05
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N12-7 (-) - N12-8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    N12-7 (-) - N12-8 (+)
    -5°C (23°F)
    5.65 to 6.95 kΩ
    N12-7 (-) - N12-8 (+)
    0°C (32°F)
    4.40 to 5.35 kΩ
    N12-7 (-) - N12-8 (+)
    5°C (41°F)
    3.40 to 4.15 kΩ
    N12-7 (-) - N12-8 (+)
    10°C (50°F)
    2.70 to 3.25 kΩ
    N12-7 (-) - N12-8 (+)
    15°C (59°F)
    2.14 to 2.58 kΩ
    N12-7 (-) - N12-8 (+)
    20°C (68°F)
    1.71 to 2.05 kΩ
    N12-7 (-) - N12-8 (+)
    25°C (77°F)
    1.38 to 1.64 kΩ
    N12-7 (-) - N12-8 (+)
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    If the resistance value is not as specified, replace the sensor.