Home › TRANSMISSION · U151F AUTOMATIC TRANSAXLE › SHIFT SOLENOID VALVE

SHIFT SOLENOID VALVE > INSPECTION

for Preparation Click here



1. INSPECT SHIFT SOLENOID VALVE SL3


    G020767E90
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



2. INSPECT SHIFT SOLENOID VALVE SLT


    G020767E92
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



3. INSPECT SHIFT SOLENOID VALVE S4


    C113971E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S4) - Solenoid Body (S4)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



4. INSPECT SHIFT SOLENOID VALVE SR


    C113977E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (SR) - Solenoid Body (SR)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



5. INSPECT SHIFT SOLENOID VALVE DSL


    C113970E11
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (DSL) - Solenoid Body (DSL)
    20°C (68°F)
    11 to 15 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



6. INSPECT SHIFT SOLENOID VALVE SL2


    G020767E89
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.



7. INSPECT SHIFT SOLENOID VALVE SL1


    G020767E88
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid valve makes an operating sound.

    If the result is not as specified, replace the shift solenoid valve.