DTC    B1419/19    Rear Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The rear room temperature sensor is installed in the rear panel to detect the rear room temperature and control the heater and air conditioning AUTO mode. The resistance of the rear room temperature sensor changes in accordance with the rear room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the rear room temperature sensor and reads voltage changes as changes in the resistance of the rear room temperature sensor.

DTC No.
DTC Detection Condition
Trouble Area
B1419/19
Open or short in rear room temperature sensor circuit
  1. Rear room temperature sensor
  2. Wire harness between rear room temperature sensor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E115796E08


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the ignition switch on (IG) and turn Techstream main switch on.

  1. Select the item below in the Data List, and read the value displayed on Techstream.

    Data List / Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temp Sensor(Rear)
    Rear room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual rear room temperature is displayed
    Open circuit: -19°C (2.2°F)
    Short circuit: 70.1°C (158.2°F)

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT REAR ROOM TEMPERATURE SENSOR


    E152647E01
  1. Remove the rear room temperature sensor .

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N13-1 (+) - N13-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    N13-1 (+) - N13-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    N13-1 (+) - N13-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    N13-1 (+) - N13-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    N13-1 (+) - N13-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    N13-1 (+) - N13-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    N13-1 (+) - N13-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    N13-1 (+) - N13-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    N13-1 (+) - N13-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    N13-1 (+) - N13-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    N13-1 (+) - N13-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE REAR ROOM TEMPERATURE SENSOR
OK


3.CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E153086E02
  1. Disconnect the N13 sensor connector.

  1. Disconnect the D38 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N13-1 - D38-17 (TR)
    Always
    Below 1 Ω
    N13-2 - D38-7 (SG-6)
    Always
    Below 1 Ω
    N13-1 - Body ground
    Always
    1 MΩ or higher
    N13-2 - Body ground
    Always
    1 MΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER