Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0607    Control Module Performance

for Preparation Click here


DESCRIPTION

The ECM continuously monitors its main and sub CPUs. This self-check ensures that the ECM is functioning properly. If outputs from the CPUs are different and deviate from the standards, the ECM will illuminate the MIL and set a DTC immediately.

DTC No.
DTC Detection Condition
Trouble Area
P0607
  1. ECM main CPU error
  2. ECM sub CPU error
ECM

NOTICE:
First check for an exhaust gas leak around the heated oxygen sensor if P0606 is present. An exhaust gas leak generates noise in the heated oxygen sensor output. The ECM may interpret this as an heated oxygen sensor transistor malfunction.


MONITOR STRATEGY


Related DTC
P0607: ECM CPU malfunction
Required sensors/Components
ECM
Frequency of Operation
Continuous
Duration
Within 1 second
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor runs whenever the following DTCs are not present
None

TYPICAL MALFUNCTION THRESHOLDS


Either of the following conditions is met:
Condition A or B
A. All of the following conditions are met:
Conditions (a), (b) and (c)
(a) CPU reset
1 time or more
(b) Learned throttle position - learned accelerator pedal position
0.4 V or more
(c) Throttle actuator
OFF
B. CPU reset
2 times or more

INSPECTION PROCEDURE

1.CHECK WHETHER DTC OUTPUT RECURS (IN ADDITION TO DTC P0607)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Clear the DTC.

  1. Turn the ignition switch off.

  1. Disconnect the battery negative terminal and wait for 1 minute.

  1. Connect the battery negative terminal.

  1. Turn the ignition switch on (IG).

  1. Select the following menu items: Powertrain / Engine and ECT / Trouble Code.

  1. Read the DTCs.

    Result:
    Display (DTC output)
    Proceed to
    P0607
    A
    No output DTC
    B



B
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A

REPLACE ECM (Click here)