VACUUM SWITCHING VALVE > INSPECTION |
| 1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY |
![]() |
Inspect VSV operation.
Using an ohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
Inspect the VSV for a short to ground.
![]() |
Using an ohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 2 - Body ground | 20°C (68°F) | 10 kΩ or higher |
![]() |
Inspect VSV operation.
Check that air flows from port E to the filter.
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If operation is not as specified, replace the VSV.