INTAKE MANIFOLD > INSPECTION |
| 1. INSPECT INTAKE MANIFOLD |
![]() |
Cylinder head side:
Using a precision straightedge and feeler gauge, measure the surface contacting the cylinder head for warpage.
Surge tank side:
Using a precision straightedge and feeler gauge, measure the surface contacting the surge tank for warpage.