COOLANT (for Inverter) > REPLACEMENT |
| 1. REMOVE NO. 2 ENGINE ROOM SIDE COVER LH |
![]() |
Remove the engine room side cover.
| 2. DRAIN COOLANT (for Inverter) |
Remove the inverter reserve tank cap.
![]() |
Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.
Install the plug with a new gasket.
| 3. ADD COOLANT (for Inverter) |
| DTC Code | Detection Item |
| P0A01-725 | Motor Electronics Coolant Temperature Sensor Circuit Range / Performance |
| P0A01-726 | Motor Electronics Coolant Temperature Sensor Circuit Range / Performance |
| P0A78-284 | Drive Motor "A" Inverter Performance |
| P0A7A-322 | Generator Inverter Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0A94-553 | DC / DC Converter Performance |
| P0AEE-276 | Motor Inverter Temperature Sensor "A" Circuit Range / Performance |
| P0AEE-277 | Motor Inverter Temperature Sensor "A" Circuit Range / Performance |
| P3221-314 | Generator Inverter Temperature Sensor Circuit Range / Performance |
| P3221-315 | Generator Inverter Temperature Sensor Circuit Range / Performance |
| P3226-562 | DC/DC Boost Converter Temperature Sensor |
| P3226-563 | DC/DC Boost Converter Temperature Sensor |
![]() |
Loosen the bleeder plug shown in the illustration and connect a hose.
Add coolant to the reserve tank.
![]() |
Add coolant until the level of coolant in the hose attached to the bleeder plug reaches the same level as the FULL line of the reserve tank.
When using the Techstream:
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
On the Techstream, enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Keep the coolant at the FULL level in the reserve tank to compensate for the drop in coolant level when the air bleeds.
When not using the Techstream:
Turn the power switch on (READY). [*1]
Turn the power switch off and add coolant to the FULL level because the coolant level drops as the air bleeds. [*2]
Repeat steps [*1] and [*2] until air bleeding from the coolant system is completed.
When the air is completely bled from the coolant system, tighten the plug.
![]() |
Add coolant to the FULL mark of the reserve tank.
| 4. INSPECT FOR COOLANT LEAKS (for Inverter) |
Remove the reserve tank cap.
![]() |
Install the radiator cap tester.
Pump the radiator cap tester to 37 kPa (0.38 kgf/ cm2, 5.4 psi), and then check that the pressure does not drop.
Reinstall the reserve tank cap.
| 5. INSTALL NO. 2 ENGINE ROOM SIDE COVER LH |
![]() |
Fit the clips and install the No. 2 engine room side cover LH.