Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1423/23    Pressure Sensor Circuit

for Preparation Click here


DESCRIPTION

This DTC is output if refrigerant pressure on the high pressure side is extremely low (0.176 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.03 MPa (32.0 kgf/cm2, 440 psi) or more). The pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the air conditioning amplifier. The air conditioning amplifier converts this signal to a pressure value according to the sensor characteristics, to control the compressor.

DTC No.
DTC Detection Condition
Trouble Area
B1423/23
  1. Open or short in pressure sensor circuit
  2. Refrigerant pressure on the high pressure side is extremely low (0.176 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.03 MPa (32.0 kgf/cm2, 440 psi) or more).
  1. A/C Pressure sensor
  2. Harness or connector between pressure sensor and air conditioning amplifier
  3. Air conditioning amplifier
  4. Expansion valve (blocked, stuck)
  5. Condenser (blocked, deterioration of cooling capacity due to dirt)
  6. Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)
  7. Cooling fan system (condenser cannot be cooled down)
  8. Air conditioning system (leaks, blocked)

WIRING DIAGRAM


E159788E02


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)


    E124477E38
  1. Disconnect the connector from the air conditioning pressure sensor.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A11-3 (+) - Body ground
    Power switch on (IG)
    Approx. 4.5 to 5.5 V



NG
Go to step 5
OK


2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)


    E124477E39
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A11-1 (-) - Body ground
    Always
    Below 1 Ω



NG
Go to step 6
OK


3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
  1. Reconnect the connector to the air conditioning pressure sensor.



    E124471E40
  1. Remove the air conditioning amplifier with the connectors still connected.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D37-9 (PRE) - Body ground
    Power switch on (IG)
    (A/C: OFF)
    0.5 to 4.8 V

    HINT:
    If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier, air conditioning pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



NG
Go to step 7
OK


4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)


  1. Measure the voltage when the following conditions are satisfied.

    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    MAX COLD
    Blower Speed
    HI
    A/C Switch
    ON
    R/F Switch
    RECIRCULATION
    Interior Temperature
    25 to 35°C (77 to 95°F)

    NOTICE:
    1. If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
    2. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.

    HINT:
    When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.



      E124471E41
    1. Measure the voltage according to the value(s) in the table below.

      Standard voltage:
      Tester Connection
      Condition
      Specified Condition
      D37-9 (PRE) - Body ground
      Power switch on (IG)
      (A/C: ON)
      0.5 to 4.8 V

      Result:
      Result
      Proceed to
      OK (When troubleshooting according to DTC)
      A
      OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE)
      B
      NG
      C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
Go to step 13
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)


    E143742E81
  1. Disconnect the connector from the air conditioning amplifier.



    E124477E40
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A11-3 (+) - D37-10 (S5-3)
    Always
    Below 1 Ω
    D37-10 (S5-3) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER  

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)


    E143742E82
  1. Disconnect the connector from the air conditioning amplifier.



    E124477E41
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A11-1 (-) - D37-13 (SG-2)
    Always
    Below 1 Ω
    D37-13 (SG-2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER  

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)


    E143742E83
  1. Disconnect the connector from the air conditioning amplifier.



    E124477E42
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A11-2 (PR) - D37-9 (PRE)
    Always
    Below 1 Ω
    D37-9 (PRE) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.INSPECT FOR AIR CONDITIONING SYSTEM LEAK
  1. Install a manifold gauge set.

  1. Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.

  1. Evacuate the air conditioning system and check that vacuum can be maintained in it.

    OK:
    Vacuum can be maintained in the Air Conditioning system.

    HINT:
    If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.



NG
Go to step 12
OK


9.CHARGE REFRIGERANT
  1. Add an appropriate amount of refrigerant (Click here).


NEXT


10.RECHECK FOR DTC
  1. Recheck for DTCs when the following conditions are satisfied.

    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    MAX COLD
    Blower Speed
    HI
    A/C Switch
    ON
    R/F Switch
    RECIRCULATION
    Interior Temperature
    25 to 35°C (77 to 95°F)

    NOTICE:
    If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the A/C operates for a while.

    HINT:
    When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

    Result:
    Result
    Proceed to
    DTC B1423 is output
    A
    DTC B1423 is not output
    B

    NOTICE:
    If the DTC was set due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.



B
END
A


11.INSPECT AIR CONDITIONING PRESSURE SENSOR
  1. Install a manifold gauge set.

  1. Disconnect the connector from the air conditioning pressure sensor.



    E107326E18
  1. Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3, and the negative (-) lead to terminal 1.

  1. Connect the voltmeter's positive (+) lead to terminal 2, and the negative (-) lead to terminal 1.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    2 - 1
    Refrigerant pressure:
    0.39 to 3.187 MPa (57 to 463 psi)
    1.0 to 4.8 V



NG
REPLACE AIR CONDITIONING PRESSURE SENSOR (Click here)
OK

REPLACE AIR CONDITIONING AMPLIFIER  

12.REPAIR AIR CONDITIONING SYSTEM LEAK
  1. Identify the area where refrigerant leaks from .

  1. Repair the identified area of the air conditioning system.

  1. Evacuate the air conditioning system.


NEXT

CHARGE REFRIGERANT (Click here)  

13.INSPECT COOLING FAN SYSTEM
  1. Check if the cooling fan operates normally.

    HINT:
    1. Cooling Fan Circuit (Click here).



NG
REPAIR COOLING FAN SYSTEM
OK


14.CHARGE REFRIGERANT
  1. Use a refrigerant recovery unit to recover refrigerant.

  1. Evacuate the air conditioning system.

  1. Add an appropriate amount of refrigerant .

    HINT:
    If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.


NEXT


15.RECHECK FOR DTC
  1. Recheck for DTCs when the following conditions are satisfied.
    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    MAX COLD
    Blower Speed
    HI
    A/C Switch
    ON
    R/F Switch
    RECIRCULATION
    Interior Temperature
    25 to 35°C (77 to 95°F)

    NOTICE:
    If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.

    HINT:
    1. When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
    2. If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs. If a DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. In this case, in order complete the repair, it is necessary to replace the cooler dryer.

    Result:
    Result
    Proceed to
    DTC B1423 is output
    A
    DTC B1423 is not output
    B



B
REPLACE CONDENSER WITH COOLER DRYER
A


16.REPLACE EXPANSION VALVE
  1. Replace the expansion valve with a normal one .

    HINT:
    Replace the expansion valve with a normal one because the expansion valve is either stuck or clogged.


NEXT

CHARGE REFRIGERANT 

17.CHARGE REFRIGERANT
  1. Add an appropriate amount of refrigerant .


NEXT


18.RECHECK FOR DTC
  1. Recheck for DTCs when the following conditions are satisfied.
    Item
    Condition
    Vehicle Doors
    Fully open
    Temperature Setting
    MAX COLD
    Blower Speed
    HI
    A/C Switch
    ON
    R/F Switch
    RECIRCULATE
    Interior Temperature
    25 to 35°C (77 to 95°F)

    NOTICE:
    If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.

    HINT:
    1. When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
    2. If refrigerant pressure is not normal after replacing the expansion valve with a normal one, the condenser or pipes may be clogged with dirt, dust or other foreign matter. In this case, clean or replace the condenser or pipes.

    Result:
    Result
    Proceed to
    DTC B1423 is not output
    A
    DTC B1423 is output
    B



B
CLEAN OR REPLACE CONDENSER OR PIPE
A

END