DTC P0441 Evaporative Emission Control System Incorrect Purge Flow |
| DTC No. | Monitoring Item | DTC Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0441 | Purge VSV (Vacuum Switching Valve) stuck open | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at the start and at the end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM (Included in hybrid vehicle control ECU) determines that Purge VSV stuck open. |
| Power switch off | 2 trip |
| P0441 | Purge VSV stuck closed | After EVAP leak check is performed, Purge VSV turned ON (open), and atmospheric air is introduced into EVAP system. 0.02 inch leak pressure standard is measured at the start and at the end of the check. If pressure does not return to near atmospheric pressure, ECM (Included in hybrid vehicle control ECU) determines that purge valve stuck closed. |
| Power switch off | 2 trip |
| P0441 | Purge flow | While engine running, the following conditions are successively met:
|
| Engine running | 2 trip |
| KEY-OFF MONITOR |
Purge VSV stuck open
In operation C, the vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM (included in the hybrid vehicle control ECU) using the pressure sensor. If the stabilized system pressure is higher than [second 0.02 inch leak pressure standard x 0.2], the ECM (included in the hybrid vehicle control ECU) interprets this as the Purge VSV (Vacuum Switching Valve) being stuck open. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).
Purge VSV stuck closed
In operation D, the pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for Purge VSV monitor begins when the Purge VSV is turned ON (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa (2.25 mmHg) or more, the Purge VSV is functioning normally. If the pressure does not increase, the ECM (included in the hybrid vehicle control ECU) interprets this as the Purge VSV being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

| PURGE FLOW MONITOR |
![]() |
The purge flow monitor consists of the two step monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.
| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 10 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not present | None |
| Engine | Running |
| Engine coolant temperature | 4.4°C (40°F) or more |
| Intake air temperature | 4.4°C (40°F) or more |
| EVAP pressure sensor malfunction | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP system check | Not detected by scan tool |
| Battery voltage | 10 V or more |
| Purge duty cycle | 8% or more |
| Key-off monitor is run when all of the following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | 2.5 mph (4 km/h) or less |
| Power switch | OFF |
| Engine condition | Not running |
| Key-off duration | 5 hours or 7 hours or 9 hours and 30 minutes |
| Pressure sensor of canister pump module malfunction (P1450, P1452, P1453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of the following conditions (a) and (b) are met before power switch off: | |
| (a) Duration that vehicle is being driven | 5 minutes or more |
| (b) Purge flow | Performed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| Next sequence is run if the following condition is met: | - |
| Atmospheric pressure change for 10 seconds | Less than 0.3 kPa (2.25 mmHg) for 1 second |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2 and 3 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated within 55 seconds |
| Next sequence is run if the following condition is met: | - |
| EVAP pressure change for 10 seconds after vent valve ON (Closed) | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. Vacuum introduction time | 15 minutes or less |
| 2. FTP | Saturated |
| Next sequence is run if the following condition is met: | - |
| EVAP pressure change for 10 seconds after Purge VSV ON (Open). | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3 and 4 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated within 55 seconds |
| 4. Reference pressure difference between the first and second | 0.7 kPa (5.25 mmHg) or less |
| Next sequence is run if the following condition is met: | - |
| Canister leak when vacuum introduction was complete | Less than second reference pressure |
| Sequence 14 is run if all of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 kPa (-15 mmHg) or less, or 3 kPa (22.5 mmHg) or more |
| 2. FTP change while FVCV and vent valve are open | 0.5 kPa (3.75 mmHg) or more |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 to 3 kPa (-15 to 22.5 mmHg) |
| 2. Vacuum introduction time | 15 minutes or less |
| Next sequence is run if the following condition is met: | - |
| FTP change when vacuum introduction for fuel tank | 0.5 kPa (3.75 mmHg) |
| Next sequence is run if the following condition is met: | - |
| FTP change when FVCV closed | 0.35 kPa (2.6 mmHg) or less |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3, and 4 |
| 1. FTP 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or more |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| 4. Reference pressure difference between the second and third measurement | Less than 0.7 kPa (5.25 mmHg) |
| Sequence is run if the following condition is met: | - |
| FTP when vacuum introduction for fuel tank was complete | Less than third reference pressure |
| Next sequence is run if the following condition is met: | - |
| FTP change while FVCV and vent valve are open | Less than 0.3 kPa (2.25 mmHg) |
| Monitor is complete if the following condition is met: | - |
| Atmospheric pressure difference between sequences 1 and 8 | 0.3 kPa (2.25 mmHg) or less |
| EVAP pressure when vacuum introduction is complete | Higher than reference pressure x 0.2 |
| EVAP pressure chance after EVAP canister purge valve is open | Less than 0.3 kPa (2.25 mmHg) |
| Both of the following conditions are met: | Conditions (a) and (b) |
| (a) EVAP pressure change when purge operation is started | Less than 0.1 kPa (0.75 mmHg) |
| (b) EVAP pressure change during purge operation when vent valve is closed | Less than 0.5 kPa (3.75 mmHg) |