AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > CHECK MODE PROCEDURE |
| LIST OF OPERATION METHODS |
By operating each of the air conditioning control switches as shown in the diagram below, it is possible to enter diagnostic check mode.

| INDICATOR CHECK |
Turn the power switch off.
Turn the power switch on (IG) while pressing the air conditioning control assembly "AUTO" switch and Recirculation/Fresh switch simultaneously. Hold both switches until the indicator check screen appears.

The indicator check is automatically performed when panel diagnosis is activated. Check that the indicators light up and go off at 1 second intervals 4 times in succession.

| DTC CHECK (SENSOR CHECK) |
Start the HV system and warm it up.
Perform the indicator check.
![]() |
Read the code displayed on the panel.
If the steps are difficult to read because they change automatically, push the "DEF" switch to display the steps one at a time so that they can be read easily. The items are displayed step by step each time the "DEF" switch is pushed.
| CLEAR SENSOR CHECK CODE |

Inspect and repair or replace the malfunctioning parts.
Clear the sensor check codes.
While pressing the Fr DEF switch during sensor check mode, press the Rr DEF switch.
Perform the sensor check and confirm that normal code 00 is displayed.
| ACTUATOR CHECK |
Start the HV system and warm it up.
Perform the indicator check.
Push the Recirculation / Fresh switch to perform the actuator check.
As the actuator check is repeated from steps 0 to 9 at 1 second intervals, check the temperature and air flow visually and by hand.

| Step No. (Front display) | Blower Level | Front Air Mix Damper | Air Flow Vent | Air Inlet Damper | Cool Air By-pass | Compressor | Rear Air Mix Damper | Rear Air Flow Vent | Rear Blower Level |
| 0 | 0 | 0% | FACE | FRESH | - | OFF | 0% | Rr FACE | 0 |
| 1 | 1 | 0% | FACE | FRESH | - | OFF | 0% | Rr FACE | 1 |
| 2 | 17 | 0% | FACE | RECIRCULATE / FRESH | - | ON | 0% | Rr FACE | 17 |
| 3 | 17 | 0% | FACE | RECIRCULATE | - | ON | 0% | Rr FACE | 17 |
| 4 | 17 | 50% | B/L | RECIRCULATE | - | ON | 50% | Rr B/L | 17 |
| 5 | 17 | 50% | B/L | RECIRCULATE | - | ON | 50% | Rr B/L | 17 |
| 6 | 17 | 50% | FOOT | FRESH | - | ON | 50% | Rr FOOT | 17 |
| 7 | 17 | 100% | FOOT-0 | FRESH | - | ON | 100% | Rr FOOT | 17 |
| 8 | 17 | 100% | F/D | FRESH | - | ON | 100% | Rr FOOT | 17 |
| 9 | 31 | 100% | DEF | FRESH | - | ON | 100% | Rr FOOT | 31 |
If the steps are difficult to confirm because they change automatically, push the "DEF" switch to display the steps one at a time so that they can be confirmed easily. The items are displayed step by step each time the "DEF" switch is pushed.