POWER SWITCH > INSPECTION |
| 1. INSPECT POWER SWITCH |
Measure the resistance according to the value(s) in the table below.

| Tester Connection | Switch Condition | Specified Condition |
| 7 (SS1) - 5 (GND) | Pushed | Below 1 Ω |
| 2 (SS2) - 5 (GND) | Pushed | Below 1 Ω |
| 7 (SS1) - 5 (GND) | Not pushed | 10 kΩ or higher |
| 2 (SS2) - 5 (GND) | Not pushed | 10 kΩ or higher |
Apply battery voltage between the terminals of the switch, and check the illumination condition of the switch.

| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 11 (SWIL) Battery negative (-) → Terminal 4 (COM) or 5 (GND) | Illuminates |
| Battery positive (+) → Terminal 12 (INDS) Battery negative (-) → Terminal 4 (COM) or 5 (GND) | Illuminates |
| Battery positive (+) → Terminal 13 (INDW) Battery negative (-) → Terminal 4 (COM) or 5 (GND) | Illuminates |