POWER WINDOW CONTROL SYSTEM > FAIL-SAFE CHART |
| POWER WINDOW OPERATION IN FAIL-SAFE MODE |
| Fail mode | Fail Detection Condition |
| Pulse direction error | With the door glass going up or down, the pulse that indicates door glass operation in the opposite direction is detected for 4 seconds. |
| Pulse stop error | With the door glass going up or down, no pulse is detected for 3.5 to 4.5 seconds. |
The power window control system prohibits the following power window operation when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.
| Power window operation | Power switch on (IG) | Key-off (Within approx. 45 seconds after power switch turned off) | Key-off (After approx. 45 seconds elapsed after power switch turned off) |
| Manual UP | Operation prohibited | Operation prohibited | Operation prohibited |
| Manual DOWN | Operative (Jam protection not operative) | Operation prohibited | Operation prohibited |
| AUTO UP (hold switch at AUTO UP position) | Operative (in MANUAL mode) (Jam protection not operative) | Operation prohibited | Operation prohibited |
| AUTO UP | Operation prohibited | Operation prohibited | Operation prohibited |
| AUTO DOWN | Operation prohibited | Operation prohibited | Operation prohibited |
If the LIN communication system malfunctions (communication blackout), the power window control system prohibits the following operations.
| Power window operation | Power switch on (IG) |
| MANUAL UP | Operative (Jam protection operative) |
| MANUAL DOWN | Operative (Jam protection not operative) |
| AUTO UP (hold switch at AUTO UP position) | Operation prohibited |
| AUTO UP | Operation prohibited |
| AUTO DOWN | Operation prohibited |