Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

DTC    B1476/76    A/C Inverter Load System Malfunction

for Preparation Click here


DESCRIPTION

The compressor with motor assembly stops compressor control and outputs this DTC if the rotation load is too large or too small while controlling motor rotation in the compressor with motor assembly.
Possible causes are refrigerant gas leakage, overcharged refrigerant gas, insufficient cooling because of a condenser fan circuit malfunction, or compressor lock.

DTC No.
DTC Detection Condition
Trouble Area
B1476/76
Motor rotation load while the compressor is operating is too large or too small.
  1. Refrigerant volume
  1. Compressor with motor assembly
  1. Cooling fan system
  2. CAN communication system

WIRING DIAGRAM


E158954E03


INSPECTION PROCEDURE

1.CHECK CAN COMMUNICATION SYSTEM
  1. Using the Techstream, check if the CAN communication system is functioning normally.

    Result:
    Result
    Proceed to
    CAN DTC is not output
    A
    CAN DTC is output
    B



B
GO TO CAN COMMUNICATION SYSTEM (Click here)
A


2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG) and turn the Techstream on.

  1. Select the item below in the Active Test and then check that the fan operates.


Active Test / Air Conditioner: 
Tester Display
Test Part
Control Range
Diagnostic Note
Electrical Fan
Electrical fan
OFF, ON
-

OK:
Electrical fan operates smoothly.



NG
GO TO COOLING FAN SYSTEM (Click here)
OK


3.CHECK REFRIGERANT PRESSURE
  1. Install a manifold gauge set .



    E050573
  1. Read the manifold gauge pressure when the following conditions are established.

    1. Prepare the vehicle according to the chart below.
      Item
      Condition
      Vehicle doors
      All fully open
      Temperature setting
      MAX COLD
      Blower speed
      HI
      A/C switch
      ON
      Recirculate/Fresh switch
      RECIRCULATION
      (30 to 35°C (86 to 95°F))

      Standard pressure:
      Low pressure side:
      0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.6 psi)
      High pressure side:
      1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)



NG
CHARGE REFRIGERANT
OK

REPLACE COMPRESSOR WITH MOTOR ASSEMBLY